OI01H-3021 SR 900

1

Operating Instruction

SR 900 

Half mask APR

Revision: 03

Summary of Contents for H01-3021

Page 1: ...2020 10 05 OI01H 3021 SR 900 1 Operating Instruction SR 900 Half mask APR Revision 03...

Page 2: ...accordance with NIOSH approval label Together with Remote filter holder SR 905 according to NIOSH approval label When selecting equipment for SR 900 some of the factors that should be taken into acco...

Page 3: ...ipment is complete in accordance with the packing list and that no transport damages have occurred Packing list Half mask Pre filter Pre filter holder Cleaning tissue ID tag User instructions Storage...

Page 4: ...e combined 1 3 Place the P100 filter on top of the cartridge Grasp both protective elements Squeeze hard until you hear the P100 snap onto the cartridge a snap Attempt to pull the filter and cartridge...

Page 5: ...lter is in the internal groove of the filter mounting all around 1 6 Fit pre filter SR 221 in the pre filter holder Pre filter prevents premature clogging of the main filter The pre filter holder prev...

Page 6: ...pull the strap over your head and put it around your neck Grab the pad or cradle with one hand and the filter or cartridge with the other 2 2 Hold the mask against your face Pull the pad or cradle ove...

Page 7: ...free end of the harness strap 3 2 Pull the free end away from the neck until buckle pops open 3 3 Pull on the free end of the strap until the respirator seats comfortably on your face Use your thumb...

Page 8: ...reath and hold your breath for about 10s If the mask is tight it will be pressed against your face If any leakage is detected check the exhalation membranes exhalation valves and the gasket adjust the...

Page 9: ...covers off the membrane seats 5 2 Prise off the membranes 5 3 Press the new membrane onto the pin Carefully check that the membrane is in contact with the membrane seat all round 5 4 Press the valve...

Page 10: ...01H 3021 SR 900 10 6 1 Reach inside the respirator and gently pull out the inhalation membrane 6 2 Check the edge of the inhalation valve Gently stretch the flap until it slips over the stud 7 1 Detac...

Page 11: ...the mask by turning it a of a lap 8 2 Attach the new filter holder Make sure the gasket is mounted correctly on the filter holder 9 1 Detach the filter holder from the mask by turning it a of a lap 9...

Page 12: ...cal areas are the exhalation membranes and the membrane seats which must have clean and undamaged contact surfaces Sundstr m cleaning tissues SR 5226 are recommended for daily care If the mask is heav...

Page 13: ...e equipment The use of non genuine parts or modification of the equipment may reduce the protective function and put at risk the approvals received by the product Before use After use Annually Visual...