Page 16
880 SERIES
8.0
Altamar/Cameo/Majesta/Optima Power requirements
Sundance hot tubs are designed to provide optimum
performance and flexibility of use when connected to their
maximum electrical service. However, they are shipped
factory configured for their most common preferred
electrical connection as follows:
•
All North American 60 Hz Models: 240 VAC/50A
**
If you prefer, a qualified technician can perform a minor circuit board
modification that allows the hot tub to operate on a different electrical
service (see table below).
North American 60 Hz Altamar/Cameo/Majesta/Optima
240V/40A*
240V/50A**
240V/60A***
Voltage
240 VAC
240 VAC
240 VAC
Max. Current Draw
26A
40A
48A
Number of Wires
3
3
3
Circuit Breaker (2-Pole)
40A*
50A**
60A***
* In this configuration, the heater
will not operate
while either jets pump
is running or when the blower is running.
** In this configuration, the heater
will not operate
while both jet pumps
are running.
*** In this configuration the heater
will operate while
both jets pumps and
the blower are running.