24
Sun Blade 6048 Modular System Product Notes • April 2011
Cold Boot of CMM Causes Abnormal Chassis Fan Speed
(6876374)
This issue was fixed in ILOM 3.0.10.
Booting the chassis by unplugging and plugging in the AC power causes the fans to
run at an abnormal speed.
Workaround
Execute the following commands to return the fan speed to normal:
stop /CH
start /CH
NEM OK LED Should Have Blinking State (6864854)
This issue was fixed in ILOM 3.0.10.
The CMM requires that the NEM light the OK status LED in order to be viewed as
powered up and operational. The LED should signal the status of the switch itself
and only light the LED when its operational and blink it when the switch is not
operational or in some transitional state.
Issues Fixed in ILOM 3.0.6.11c
CMM Power/OK LED No Longer Works With ILOM
3.0.3.32 (6869525)
This issue was found in ILOM 3.0.3.32 and fixed in ILOM 3.0.6.11.
After upgrading the Sun Blade 6000 modular system CMM to ILOM version 3.0.3.32,
the CMM Power/OK LED does not turn on.