E20425-01 •
Chapter 4 Commands
231
Write Command
■
Write Command
The Write command transfers one or more blocks of data from the host to
tape.
Table 176. Write Command
Byte
Bit
7
6
5
4
3
2
1
0
0
Operation Code (0Ah)
1
Reserved Fixed
2
thru
4
(MSB)
Transfer Length
(LSB)
5
Control Byte
Parameter
Value
Fixed
Indicates the block mode for data transfer:
0 = Variable block mode.
Transfer Length specifies the length of the block in bytes to be
written. A single block is transferred from the initiator.
1 = Fixed block mode.
Transfer Length specifies the number of blocks to be
transferred to the device.
Transfer Length
Number of blocks or bytes requested