background image

Sun Microsystems, Inc.
www.sun.com

Submit comments about this document at:

http://www.sun.com/hwdocs/feedback

Sun

Integrated Lights Out Manager

(ILOM) 2.0 Supplement for Sun Fire

X4170, X4270, and X4275 Servers

Part No. 820-7629-10
March 2009, Revision A

Summary of Contents for Sun Fire X4170

Page 1: ...ww sun com Submit comments about this document at http www sun com hwdocs feedback Sun Integrated Lights Out Manager ILOM 2 0 Supplement for Sun Fire X4170 X4270 and X4275 Servers Part No 820 7629 10...

Page 2: ...lifornia 95054 Etats Unis Tous droits r serv s Sun Microsystems Inc d tient les droits de propri t intellectuels relatifs la technologie incorpor e dans le produit qui est d crit dans ce document En p...

Page 3: ...he Factory Default 6 ILOM Sideband Management 6 Configure Sideband Management Using the Web Interface 7 Configure Sideband Management Using the CLI 8 Configure Sideband Management Using the Host BIOS...

Page 4: ...d X4275 Servers March 2009 How the SYS SP SP_NEEDS_REBOOT Sensor Works 18 Sensors Reference Information 19 Temperature Sensors 20 Power Supply Fault Sensors 20 Fan and Security Sensors 21 Power Supply...

Page 5: ...ates For product updates that you can download for the Sun Fire X4170 X4172 and X4275 Servers visit the following web site http www sun com download index jsp Find the Hardware Drivers section and cli...

Page 6: ...stems 820 5828 PDF HTML Sun Fire X4170 X4270 and X4275 Servers Windows Operating System Installation Guide Installation instructions for the Windows Server operating system 820 5829 PDF HTML Sun Insta...

Page 7: ...ion that you received with your system Solaris Operating System documentation which is at http docs sun com Sun Integrated Lights Out Manager Supplement for Sun Fire X4170 X4270 and X4275 Servers ILOM...

Page 8: ...ing its documentation and welcomes your comments and suggestions You can submit your comments by going to http www sun com hwdocs feedback Please include the title and part number of your document wit...

Page 9: ...M as well as defines the purpose of ILOM s common and platform features offered in ILOM 2 0 The following topics are discussed in this chapter ILOM Overview on page 2 Supported Platform Firmware on pa...

Page 10: ...nterfaces For general information about ILOM s use and capabilities see the Sun Integrated Lights Out Manager 2 0 User s Guide 820 1188 Note For information about establishing a first time connection...

Page 11: ...e Sun Integrated Lights Out Manager 2 0 User s Guide 820 4198 Platform Specific Features ILOM 2 0 operates on many platforms supporting features that are common to all platforms Some ILOM 2 0 features...

Page 12: ...4 Sun Integrated Lights Out Manager 2 0 Supplement for Sun Fire X4170 X4270 and X4275 Servers March 2009...

Page 13: ...ting the Root Password to the Factory Default on page 6 Resetting the Root Password to the Factory Default on page 6 ILOM Sideband Management on page 6 Switch Serial Port Output Between SP and Host Co...

Page 14: ...band ports The advantage of using a sideband management port to manage the server s SP is that one less cable connection and one less network switch port is needed In configurations where a great numb...

Page 15: ...e CLI on page 8 Configure Sideband Management Using the Host BIOS Setup Utility on page 10 Configure Sideband Management Using the Web Interface 1 Log in to the ILOM web interface 2 Select Configurati...

Page 16: ...e SP NET MGT port SYS SP NET0 is the default c Click Save for the changes to take effect Configure Sideband Management Using the CLI 1 Log in to ILOM using the CLI Note Using a serial connection for t...

Page 17: ...port type the following commands set SP network pendingmanagementport SYS MB NETn Where n equals 0 1 2 or 3 set commitpending true SP network Targets Properties commitpending Cannot show property dhcp...

Page 18: ...r Use a terminal or terminal emulator connected to a computer through the serial port on the back panel of the server Connect to the server using the Sun ILOM Remote Console To configure sideband mana...

Page 19: ...275 Servers 11 2 To enter the BIOS Setup utility press the F2 key while the system is performing the power on self test POST When BIOS is started the main BIOS Setup utility top level screen appears T...

Page 20: ...12 Sun Integrated Lights Out Manager 2 0 Supplement for Sun Fire X4170 X4270 and X4275 Servers March 2009 3 In the main screen select Advanced IPMI Configuration The IPMI Configuration screen appears...

Page 21: ...ation screen appears 5 In the LAN Configuration screen do the following a Use the left and right keys to select the IP Assignment option and set it to DHCP b Use the left and right keys to select the...

Page 22: ...Serial Port Output Using the Web Interface on page 14 Switch Serial Port Output Using the CLI on page 15 Caution You should set up the network on the SP before attempting to switch the serial port own...

Page 23: ...t Settings page appears 3 To select a serial port owner click the Owner drop down list and select the desired serial port owner The drop down list enables you to select either Service Processor or Hos...

Page 24: ...does not require replacement of a faulty part however user action is needed to clear it fault security integrity compromised sys sp This fault is generated when the server s top cover is removed while...

Page 25: ...ver is in a remote or uncontrolled location How the SYS INTSW Sensor Works The SYS INTSW sensor is asserted when the chassis intrusion switch trips while the server is powered on If the AC power cords...

Page 26: ...o clear this sensor you must replace the server s cover and either reboot or power cycle the SP Assertion of the SYS SP SP_NEEDS_REBOOT sensor indicates that the SP has been placed in a degraded mode...

Page 27: ...ent Voltage and Power Sensors on page 22 Entity Presence Sensors on page 22 TABLE 2 1 Server Condition as Indicated by the SYS INTSW and SYS SP SP_NEEDS_REBOOT Sensors SYS INTSW SYS SP SP_NEEDS_REBOOT...

Page 28: ...he power supply fault sensors In the table n designates the numbers 0 n TABLE 2 2 Temperature Sensors Sensor Name Sensor Type Description SYS MB T_AMB Temperature Motherboard ambient temperature senso...

Page 29: ...is being applied to the server this sensor asserts If the top cover is subsequently replaced this sensor is de asserted For more information see Server Chassis Intrusion Sensors on page 17 SYS SP SP_N...

Page 30: ...ut current sensor SYS PSn V_OUT Voltage Power supply unit n DC output voltage sensor SYS PSn I_OUT Current Power supply unit n DC output current sensor SYS PSn INPUT_POWER Power Power supply unit n in...

Page 31: ...MB Pn Dn PRSNT Entity presence Motherboard CPUn Memory DIMM n present monitor SYS MB RISERn PRSNT Entity presence PCIe riser n present monitor SYS MB RISERn PCIen PRSNT Entity presence PCIe card n pr...

Page 32: ...24 Sun Integrated Lights Out Manager 2 0 Supplement for Sun Fire X4170 X4270 and X4275 Servers March 2009...

Page 33: ...ions supported 2 P Preboot Menu 14 product updates downloads v R related documents v root password setting 6 S sensors entity presence 22 fan 21 power 22 power supply 20 security 21 temperature 20 ser...

Page 34: ...grated Lights Out Manager 2 0 Supplement for Sun Fire X4170 X4270 and X4275 Servers March 2009 when it is asserted 18 Sun support vii T training where to find vii U UNIX commands vii W web sites third...

Reviews: