68
Sun Fire V100 Server User’s Guide • December 2001
▼
To Check the Status of the Supply Rails and
Internal Circuit Breakers
●
Type:
▼
To Check the Internal Temperature
●
Type:
This checks the server’s internal temperature, and the warning and shutdown
threshold temperatures.
# lom -v
Supply voltages:
1 5V status=ok
2 3V3 status=ok
3 +12V status=ok
4 -12V status=ok
5 VDD-CORE status=ok
System status flags (circuit breakers):
1 USB0 status=ok
2 USB1 status=ok
# lom -t
System Temperature Sensors:
1 enclosure 25 degC : warning 67 degC : shutdown 72 degC
System Over-temperature Sensors:
1 cpu status=ok
#