Chapter 4
Troubleshooting Example
57
Test the FRUs
The following FRUs exist in the host-to-switch link:
■
Switch or switch port
■
Switch-side SFP
■
Cable
■
Host HBA
To isolate the cause, perform one of the following options with the Storage
Automated Diagnostics Environment:
■
The
switchtest
in combination with the
qlctest
■
The
linktest
Storage Automated Diagnostics Environment
switchtest
and
qlctest
Tests
1. Remove one end of the cable of the HBA-switch link
2. Insert loopback plug into the HBA
3. Run the
qlctest
■
If the test fails, replace HBA and re-run the
qlctest
■
If the test passes, continue below
4. Insert loopback plug into Switch SFP/Port
5. Run the
switchtest
■
If the test passes, most likely problem is cable
■
If the test fails, continue below
6. Replace SFP and re-run the
switchtest
■
If the test passes, the most likely problem was SFP connector
■
If the test fails, the most likely problem is the switch port or the entire switch
Summary of Contents for StorEdge
Page 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...