Appendix C
Brocade Communications Systems Error Messages
123
▼
To Display Error Messages from the Front Panel
1. From the front panel, select the Status menu.
2. Select Error Log.
3. Scroll through the error log. If no errors are encountered, the panel displays
No Error
.
Diagnostic Error Message Formats
If any port fails during a diagnostic test, it is marked BAD in the status display.
To retest a port that has been marked BAD, clear the port and set to OK using the
diagClearError
(
port#
) command. This command clears the port status only
and does not clear the logs or change the port’s condition. The
diagClearError
(
port#
) command should only be used during diagnostic procedures to reset a bad
port for retest.
Some messages contain the following abbreviations:
■
sb = Should Be
■
er = Bits in error
Note –
If you run the
portStateShow
or the
diagShow
command prior to
running a test, errors may appear as a result of the normal synchronization process.
These errors should be addressed if the number of errors found increases when
running the
portStateShow
command again.
TABLE C-1
Probable Failure Actions
Failed Test
Action
ramTest
replace DRAM module or mainboard assembly
portRegTest
replace mainboard assembly
centralMemoryTest
replace mainboard assembly
cmiTest
replace mainboard assembly
cmemRetentionTest
replace mainboard assembly
sramRetentionTest
replace mainboard assembly
camTest
replace mainboard assembly
Summary of Contents for StorEdge
Page 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...