To Troubleshoot the Array When the Subsystem
LED Is Amber
1. Check the status LEDs on the power supplies and fan canisters in the rear of the
D2 array.
Refer to
, “LEDs on Power Supplies and Fan Canisters” on page 1-17 for
the location of the status LEDs.
2. If there is a fault on one of the fan canisters, re-seat the canister by following the
instructions for replacing a fan canister in “To Remove and Replace a Fan
Canister” on page 4-14.
3. If there is a fault on one of the power supplies, check the following:
■
Is the power cord properly seated and is power present?
■
Is the power switch turned on?
■
Re-seat the power supply by following the instructions for replacing a power
supply. See “To Remove and Replace a Power Supply” on page 4-16.