1-2
Sun StorEdge D2 Array Installation, Operation, and Service Manual • February 2002
1.1
Description
The Sun StorEdge D2 array is a four rack unit (4 RU) JBOD (Just a Bunch of Disks),
direct-attach, high-performance. storage subsystem containing up to twelve Ultra3
disks. The array can be managed with storage management software, such as
Solstice DiskSuite software or VERITAS Volume Manager installed on the host.
An environmental services module (ESM) monitors the status of the enclosure using
light-emitting-diodes (LEDs) to display each component’s health and activity.
Note –
The terms “flashing” and “blinking” have slightly different meanings when
they are used in the description of an LED. The rate of “flashing” varies according to
the rate of occurrence of whatever events the LED is indicating, while the rate of
“blinking” is fixed.
The ESM also enables remote environmental monitoring from a host by means of the
SCSI Accessed Fault-tolerant Enclosure
(
SAF-TE) protocol through the low voltage
differential (LVD) SCSI connection.
Each ESM has two independent Ultra3 160 MB SCSI bus connections. Daisy-chaining
is not supported.
Summary of Contents for StorEdge D2
Page 10: ...x Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Page 50: ...2 12 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Page 92: ...4 28 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Page 98: ...B 2 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Page 104: ...B 8 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Page 114: ...B 18 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Page 118: ...Index 4 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...