Operating in Manual Mode
3-24
Revision P
95693
Mounting a Cartridge into a T9840 Drive
Important:
T9840A/B and T9840C VolSafe cartridges are not interchangeable. T9840C
tape drives can read the 20-GB VolSafe tape cartridges used in T9840A and T9840B
drives, but cannot write to them. The 40-GB VolSafe tape cartridges used in T9840C
drives cause a load error when mounted in a T9840A or T9840B drive.
“T9840 and T9940 Tape Drives” on page 4-5
for more information.
To load the cartridge in a T9840 drive:
1. Follow the steps in
“Mounting and Dismounting Cartridge Tapes” on page 3-19
2. Insert the cartridge into the drive using the direction shown in
3. Wait for one of the following messages to display and take the appropriate
action, if necessary:
•
The
Ready A
message displays when the drive is VolSafe-enabled and
loaded with a write-enabled VolSafe cartridge.
•
The
Ready F
(File Protected) message displays when a write-protected
cartridge loads successfully.
•
The
Ready U
(File Unprotected) message displays when a cartridge
that is not write-protected loads successfully.
•
The
NTReady
message displays when the tape in the cartridge has lost
tension. Follow the instructions outlined in the
T9840 Tape Drive User’s Reference
Manual
to correct this condition.
•
The
LOAD
xxxx
message displays when the cartridge unsuccessfully
loads, where the
xxxx
is a fault symptom code.
Summary of Contents for StorageTek TIMBERWOLF 9740
Page 1: ...StorageTek TIMBERWOLF 9740 Tape Library Hardware Operator s Guide 95693 Revision P ...
Page 2: ......
Page 3: ...TimberWolf 9740 Tape Library Hardware Operator s Guide ...
Page 6: ...iv Revision P 95693 ...
Page 12: ...Tables x Revision P 95693 ...
Page 16: ...xiv Revision P 95693 ...
Page 62: ...Operating in Manual Mode 3 30 Revision P 95693 ...
Page 90: ...Environmental Specifications A 20 Revision P 95693 ...
Page 94: ...Glossary Glossary 4 Revision P 95693 ...
Page 99: ......