Chapter 4
FRU Replacement Preparation
4-13
4.5.3
Powering on the Server
This section explains how to power on the server.
4.5.3.1
Power-on by Using the XSCF Command
1. Verify that the server has enough power supply units to operate in the desired
configuration.
2. Connect all the power cords to AC power outlets.
3. Verify that the XSCF STANDBY LED on the operator panel is on.
4. Turn the mode switch on the operator panel to the desired mode position
(Locked or Service).
5. A user with platadm or fieldeng authority must log in to the XSCF shell and
type the
poweron
command.
Soon, the following activity is executed:
■
The POWER LED on the operator panel is turned on.
■
The power-on self-test (POST) is executed.
Then, the server is completely powered on.
Note –
If automatic startup of the Solaris OS is specified, use the
sendbreak -d
domain_id
command of the XSCF shell to display the ok prompt after the display
console banner is displayed but before the system starts booting the Solaris OS.
For details, see the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers
XSCF User's Guide
.
4.5.3.2
Power-on by Using the Operator Panel
1. Verify that the server has enough power supply units to operate in the desired
configuration.
2. Connect all the power cords to AC power outlets.
3. Verify that the XSCF STANDBY LED on the operator panel is on.
4. Turn the mode switch on the operator panel to the desired mode position
(Locked or Service).
XSCF>
poweron -a
Summary of Contents for SPARC Series
Page 4: ......
Page 12: ...xii SPARC Enterprise M3000 Server Service Manual January 2009 ...
Page 22: ...1 6 SPARC Enterprise M3000 Server Service Manual January 2009 ...
Page 102: ...6 10 SPARC Enterprise M3000 Server Service Manual January 2009 ...
Page 108: ...7 6 SPARC Enterprise M3000 Server Service Manual January 2009 ...
Page 114: ...8 6 SPARC Enterprise M3000 Server Service Manual January 2009 ...
Page 120: ...9 6 SPARC Enterprise M3000 Server Service Manual January 2009 ...
Page 132: ...11 6 SPARC Enterprise M3000 Server Service Manual January 2009 ...
Page 138: ...12 6 SPARC Enterprise M3000 Server Service Manual January 2009 ...
Page 144: ...13 6 SPARC Enterprise M3000 Server Service Manual January 2009 ...
Page 152: ...14 8 SPARC Enterprise M3000 Server Service Manual January 2009 ...
Page 158: ...15 6 SPARC Enterprise M3000 Server Service Manual January 2009 ...
Page 162: ...A 4 SPARC Enterprise M3000 Server Service Manual January 2009 ...
Page 168: ...B 6 SPARC Enterprise M3000 Server Service Manual January 2009 ...
Page 188: ...E 8 SPARC Enterprise M3000 Server Service Manual January 2009 ...