Chapter 4
Firmware and Blade Server Management
4-15
Note –
To store parameter changes, you can also power cycle the system using the
front panel Power button.
4.5.1.2
To Disable Automatic System Recovery
1. At the
ok
prompt, type:
2. To cause the parameter changes to take effect, type:
The system permanently stores the parameter change.
Note –
To store parameter changes, you can also power cycle the system using the
front panel Power button.
After you disable the automatic system recovery (ASR) feature, it is not activated
again until you re-enable it.
4.6
Hot-Swap Information
The Sun Netra CP3060 blade server supports hot-swapping and includes a blue
Hot-Swap LED.
4.6.1
Hot-Swapping the Sun Netra CP3060 Blade Server
If the Solaris OS is running on a Sun Netra CP3060 blade server and you open the
blade server’s latches, you see a message that the operating system will shut down
in one minute. When the blue LED on the blade server lights steadily, you can safely
remove the blade server.
ok
setenv auto-boot-on-error? false
TABLE 4-7
ok
reset-all