![Sun Microsystems 5500 Reference Manual Download Page 158](http://html1.mh-extra.com/html/sun-microsystems/5500/5500_reference-manual_1392445158.webp)
10-6
Sun Enterprise 6500/5500/4500 Systems Reference Manual • April 1998
10.5
Defective Disk Board
The disk board is hot-pluggable.
FIGURE 10-5
Diagnosing Disk Board Problems
INDICATION
System error message or
LED code identifies a
specific board
Board not identified or
intermittent problem
TEST/PROCEDURE
Locate indicated board.
Check LEDs on board to verify
ASR has deactivated the
board.
Set the SCSI IDs of the
replacement drives.
Replace the board or device.
Board is not active until system is
booted.
Check
/var/adm/messages
Locate defective SCSI device
with
probe-scsi-all
(OpenBoot command).
Check ID jumpers on board.
REFERENCE
LED code must be Off-On-Off.
See
.
See Appendix C “SCSI Devices.”
Begin
End
Summary of Contents for 5500
Page 12: ...xii Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Page 20: ...xx Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Page 89: ...Chapter 4 I O Boards and Components 4 31 FIGURE 4 27 PCI Card Removal Catch mechanism ...
Page 94: ...4 36 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Page 128: ...7 14 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Page 172: ...11 10 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Page 184: ...12 12 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Page 208: ...B 20 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Page 272: ...F 24 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...
Page 290: ...G 18 Sun Enterprise 6500 5500 4500 Systems Reference Manual April 1998 ...