S One
User’s Manual
OPOS
3-15
Media calibration ensures that the sensor can recognize the marks. OPOS is factory calibrated
to work with a wide range of materials. However, certain materials, such as those with a high
gloss, may not work with the default settings. Before working with such materials, perform a
media calibration test. This test will alter OPOS’s sensitivity so that it will read the marks with
greater reliability. Print a square of at least 4x4 cm on the media used. Use the same ink as for
printing the registration marks.
NOTE:
If the media calibration is completed and the results have not improved,
reset the media calibration value to the default value.
Perform the media calibration:
1.
Switch the cutter on and load the vinyl with the printed square.
2.
Tap
.
3.
Scroll down with the arrow
and tap
Calibrations
.
4.
Tap
Calibrate media
(OPOS)
.
5.
Tap
Measure
.
6.
Use the arrows to place the
knife in a white area.
7.
Tap
to confirm.
The cutter will make a
circular movement while it
measures the reflection of
the media.
8.
Use the arrows to place the
knife in a printed area.
9.
Tap
to confirm.
S1D160
50000 x 145 mm
Knife
700 mm/s
90 g
Configuration 1
LAN 192.168.10.2
FlexCut
Tool
Actions
Settings
Calibrations
Configuration
Menu
Length calibration
Calibrate OPOS
Length calibration
Media sensor setup
Calibrate OPOS
Calibrate media (OPOS)
Calibrations
Measure
Set
Reset default
Calibrate media (OPOS)
Set tool
above white
area.
X
Y 50.00
30.00
Calibrate media (OPOS)
Set tool
above white
area.
X 0.00 Y 50.00
3
Calibrate media (OPOS)
Set tool
above
printed
area.
X
Y 50.00
85.00
Calibrate media (OPOS)
Set tool
above
printed
area.
X
.00 Y 50.00
85
Calibrate media (OPOS)
3.4.2
Media calibration