26
Fig.29-b In a case of capacitor start and capacitor-run type 0.1kW-0.4kW
MC: Electromagnetic contactor
OLR: Overload relay or thermal relay
Rotation shifting switch
These should be
furnished by the
customer.
· Connection to Z1 and Z2 shall be exchanged with each other when reverse rotation is
necessary if the motor is provided only for rotation in one direction.
· A capacitor is built in the terminal box of capacitor start and capacitor-run type 0.1kW-0.4kW.
· Do not open water-proof dust-proof box for
water-proof type
, otherwise electrical shock, fire
or damage to the equipment may result.
· A capacitor is not water-proofed for
water-proof type
.
· This drawing shows for a motor based on standard specification for domestic market.
Motor based on overseas standard shall be referred to us.
100V Class
200V Class
Motor
U
1
U
2
V
1
R
S
OLR
MC
V
2
Z
2
Z
1
U
1
Z
2
U
2
V
1
V
2
Z
1
R
OLR
S
Forward
Reverese
Motor
U
1
U
2
Z
1
R
S
OLR
MC
V
1
V
2
Z
2
R
OLR
S
U
1
U
2
Z
1
V
1
V
2
Z
2
Motor
Forward
Reverse
Operation
in
one
direction
Operating
in
both
directions
Control panel
Terminal box
Control panel
Terminal box
Control panel
Terminal box
Control panel
Terminal box
6. Wiring