ECO ARC 600
6-9
Revision 1/10/08
6.4
Spray wires are not pushed forward, not melted down, electric arc
breaks off, chatters
Indication
Cause
Remedy
Power supply
Power supply
One phase is missing
Only specialist staff is allo-
wed to work at electrical
appliances.
Check all three phases.
Check fuse in your three
phase current system.
Three phase current supply
Loose connection of plug /
cable
Check plug / cable connec-
tions.
Decoiling device
Not smooth running
Must run smoothly.
If not clean and grease.
(s. maintenance).
Spray wire badly spooled.
Forms loops.
Wire transport is blocked
Clip off spray wire. Round off
edges.
Re-insert spray wire.
Spray wire
Bad quality
Use different spray wire.
Get advised by SMOSU-
customer service.
ON OFF ON
System OFF
Error
Undervoltage
System OFF
Error Underload