5.2
Setting-up system
5.2.1 Introducing spray wire
•
Put wire spool on its decoiling device.
The wire must run off the spool from the top.
Tighten spring breaks slightly so the spool is not running.
Alternatively:
Guide wire from drums over the deflection rollers.
•
Clip off wire tips, round them of with a file and straighten them.
•
Insert wire through the wire guide tubes up against the push drive.
•
Keep wire pressure levers (11) pushed successively and guide
wire between the pressure rolls through the push drive approx.
200 mm into the hose package.
•
Make sure the wire is positioned in the correct groove.
5.2.2 Changing spray wire
•
Clip off wire in front of push drive and spray the rest of the wire.
Pull out rest of wire from the contact nozzles with a nipper.
•
A new/different wire can be installed as discribed before.