COMPONENT DESCRIPTION
START-UP
Line Pressure
Dry Side
Wet Side
LEGEND
FIGURE 3-3.
108MM 15-50hP VFD MPC CONTROL SYSTEM (START-UP) R00
When the compressor is started, a 10-second load delay is activated to ensure the compressor is up to
proper speed and minimum design pressure has been achieved. At this time the system is in a blowdown
condition, during which control air is supplied back to the inlet valve to keep it in a closed position and a
controlled amount of air is vented out of the sump tank. A predetermined blowdown orifice and an inlet
bypass orifice will maintain the unload sump pressure, nominal 30–40 psig (2.1–2.8 bar).
. At this time, the motor speed is at the minimum set point (VFD only).