SPECIFICATIONS
2.1.6 40D, H40D, HH40D
COMPRESSOR DATA
40D
H40D
HH40D
Capacity
acfm
166
115
110
Pressure @ Full Load
psig (bar)
125 (8.6)
150 (10.3)
175 (12.1)
Minimum Pressure
psig (bar)
60 (4.1)
70 (4.8)
70 (4.8)
Motor Output (60 Hz)
hp (kW)
40 (29.8)
40 (29.8)
40 (29.8)
Motor Speed
rpm
3,550
3,550
3,550
Motor Output @ Full Load
hp (kW)
47 (35.0)
41 (30.6)
43 (32.1)
Motor Output @ 100 psig
hp (kW)
42 (31.3)
Driven Rotor Coupling
Direct
Direct
Direct
Drive Ratio
1
1
1
Rotor Diameter
mm
108
108
108
COOLING DATA (AIR-COOLED)
40D
H40D
HH40D
Fan Airflow
cfm
3,500
3,500
3,500
Maximum Duct Loss
inH
2
O
0.25
0.25
0.25
Aftercooler Approach
°F (°C)
15 (-9)
15 (-9)
15 (-9)
Heat Rejection
btu/hr (kW)
106,300 (31.1)
106,300 (31.1)
106,300 (31.1)
Fluid Capacity
gallons (liters) 3.5 (13)
3.5 (13)
3.5 (13)
COOLING DATA (WATER-COOLED)
40D
H40D
HH40D
Water Flow with 60°F Water
gpm (L/min)
4.5 (17.0)
4.5 (17.0)
4.5 (17.0)
Water Flow with 70°F Water
gpm (L/min)
5.8 (21.0)
5.8 (21.0)
5.8 (21.0)
Water Flow with 80°F Water
gpm (L/min)
7.6 (28.8)
7.6 (28.8)
7.6 (28.8)
Maximum Water Temperature °F (°C)
85 (29)
85 (29)
85 (29)
Water Connection In-Out
NPT
3/4 - 3/4
3/4 - 3/4
3/4 - 3/4
SOUND DATA
40D
H40D
HH40D
Air-Cooled (Open)
dba @ 1m
85
85
85
Air-Cooled (Enclosed)
dba @ 1m
80
80
80
Water-Cooled (Open)
dba @ 1m
80
80
80
Water-Cooled (Enclosed)
dba @ 1m
80
80
80
DISCHARGE PIPING
40D
H40D
HH40D
Air-Cooled (Base-Mounted)
NPT
1-1/4
1-1/4
1-1/4
Water-Cooled (Base-Mounted) NPT
1-1/2
1-1/2
1-1/2
Tank-Mounted (Tank End)
NPT
2
2
2
ELECTRICAL DATA
40D
H40D
HH40D
Motor FLA @ 575V
amps
36.0
36
36.0
Motor FLA @ 460V
amps
45.0
45.0
45.0
Motor FLA @ 230V
amps
90.0
90.0
90.0
Motor FLA @ 208V
amps
99.5
99.5
99.5
Motor FLA @ 200V
amps
102.0
102
102.0
Starter Enclosure Rating
NEMA
1
1
1
Control Voltage
volts
110
110
110
Motor Enclosure
NEMA
ODP
ODP
ODP
Motor Insulation Class
NEMA
F
F
F
Motor Service Factor
NEMA
1.25
1.25
1.25
Motor Maximum Starts/Hour
4
4
4
Summary of Contents for 15D
Page 6: ...vi About This Manual ...
Page 12: ...4 Introduction ...
Page 20: ...12 Specifications 2 2 DIMENSIONS OPEN BASE MOUNT AIR COOLED Figure 2 1 GA 15 40D AC BM OPEN ...
Page 30: ...22 Specifications 2 12 PIPING AND INSTRUMENTATION AIR COOLED Figure 2 11 GA P I S R02 ...
Page 34: ...26 Specifications ...
Page 66: ...58 Troubleshooting ...
Page 112: ...NOTES ...
Page 113: ...NOTES ...