SULLIVAN-PALATEK______________________________
9
SECTION 2 - SPECIFICATIONS
MODEL
125G 150G 200G 250G
MOTOR
SIZE
(HP)
125 150 200 250
AIR DELIVER (CFM)
600
715
1000
1000
MAX. FULL LOAD PRESSURE
125
125
125
150
MIN. FULL LOAD PRESSURE
70
70
70
70
LUBRICOOLANT CAP GAL.
SYS/TANK
33/25
33/25
33/25
33/25
DIMENSIONS:
OPEN
ENCLOSED
OPEN
LENGTH
96
96
WIDTH
58
58
HEIGHT
66
3/8
67
NOTE: SEE INSTALLATION DRAWINGS ON PAGES 57-61 OF THIS MANUAL
2.1
DATA AND DIMENSIONS
SULLIVAN-PALATEK reserves the right to change the design or construction of the
above compressors, or to offer them with options which will cause subject equipment to
differ from the above specifications, without reference to any descriptions in this manual.
2.2 LUBRICATION
GUIDE
SULLIVAN-PALATEK recommends using Palasyn 45 synthetic lubricoolant for normal
plant-air service. For compressors running two or three shift operations, extended life
lubricants such as Pallube 32p, or Pal-Extra 44 are offered as factory fill. Also, where
incidental food contact may happen, we offer a Food Grade 32FLL.
For extreme environments (i.e. fine particulate, caustic, acidic, or oxidant atmospheres)
contact the factory for lubricant recommendations. Also, for such conditions we would
suggest oil analysis every 1000 hours.
Mixing of these or any other type of oil or synthetic fluid will void the 5-year compressor
unit warranty and could result in greatly increased maintenance and service expenses.
2.3 APPLICATION
GUIDE
Ambient Temperature Range: +35° to +104° F (+1° to +40° C). The lower temperature
limit is to prevent freeze-up of condensate in the aftercooler and/or control lines. When
operating these compressors for plant air in food or beverage processing industries,
contact the factory for a Lubricoolant that is FDA approved for “incidental contact with
foodstuffs." For instrument-grade air, contact the factory for recommendations related to
specialized compressed air preparation accessories.
Whenever a SULLIVAN-PALATEK rotary screw compressor is installed in parallel with a
reciprocating type of compressor, it is imperative that the SULLIVAN-PALATEK be the
“lead” machine and the reciprocating the “lag” machine. That is, the SULLIVAN-
PALATEK should be the first to start and the last to stop when being operated in the
“automatic stop/start” mode, or the first to load and the last to unload, when in the
“continuous run” mode. It should require the least electrical power consumption for the
combination. Maximum number of starts per hour:
Motor HP
125
150
200
250
Starts/Hr 4
4
4
4
Summary of Contents for 125G
Page 12: ...______________________________SULLIVAN PALATEK 12 CONTROL SCHEMATIC ...
Page 18: ...______________________________SULLIVAN PALATEK 18 4 5b WIRING DIAGRAM Y DELTA START OPTIONAL ...
Page 28: ...______________________________SULLIVAN PALATEK 28 PARTS LISTING ...
Page 31: ...SULLIVAN PALATEK______________________________ 31 DRIVE AND BASE ASSEMBLY ...
Page 32: ...______________________________SULLIVAN PALATEK 32 7 3 DRIVE AND BASE ASSEMBLY PARTS LIST ...
Page 33: ...SULLIVAN PALATEK______________________________ 33 LUBRICATION AND COOLING SYSTEM AIR COOLED ...
Page 37: ...SULLIVAN PALATEK______________________________ 37 LUBRICATION COOLING SYSTEM W C 200 250 ...
Page 38: ...______________________________SULLIVAN PALATEK 38 7 5b LUBRICATION COOLING SYSTEM W C 200 250 ...
Page 39: ...SULLIVAN PALATEK______________________________ 39 INLET AND CAPACITY CONTROL SYSTEM ...
Page 41: ...SULLIVAN PALATEK______________________________ 41 DISCHARGE SYSTEM 125 150 HP ...
Page 43: ...SULLIVAN PALATEK______________________________ 43 DISCHARGE SYSTEM 200 250 HP ...
Page 45: ...SULLIVAN PALATEK______________________________ 45 OPEN COMPRESSOR ELECTRICAL CONTROL PARTS ...
Page 47: ...SULLIVAN PALATEK______________________________ 47 ENCLOSED COMPRESSOR CONTROL PARTS ...
Page 48: ...______________________________SULLIVAN PALATEK 48 7 8b ENCLOSED COMPRESSOR CONTROL PARTS ...
Page 49: ...SULLIVAN PALATEK______________________________ 49 AIR COOLED ENCLOSURE 125 250 ...
Page 50: ...______________________________SULLIVAN PALATEK 50 7 10a AIR COOLED ENCLOSURE 125 150 ...
Page 51: ...SULLIVAN PALATEK______________________________ 51 AIR COOLED ENCLOSURE 200 250 ...
Page 52: ...______________________________SULLIVAN PALATEK 52 7 10b AIR COOLED ENCLOSURE 200 250 ...
Page 53: ...SULLIVAN PALATEK______________________________ 53 WATER COOLED ENCLOSURE ...
Page 54: ...______________________________SULLIVAN PALATEK 54 7 11 WATER COOLED ENCLOSURE ...
Page 56: ...______________________________SULLIVAN PALATEK 56 7 12b DECAL AND IDENTIFICATION ...