CON’T.
SYMPTOM PROBABLE CAUSES AND REMEDIES
B. MACHINE SHUTS DOWN WITH AIR
DEMAND PRESENT
4. Monitor temperature at micro processor:
normal discharge temperature should be
100-110° F (37-43° C) above ambient;
control is set to trip at 235-245°F (112-
118°C).
a. Cooling air flow restricted. Clean
cooler and check for proper
ventilation.
b. Ambient temperature is too high.
Provide sufficient ventilation.
c. Low lubricoolant level. Add
lubricoolant.
d. Clogged oil filter. Change the oil filter
element.
e. Thermostat not working properly.
Replace.
f.
Check for proper cooling fan
operation. Fan should always be
running between 165° to 190°F.
SYMPTOM PROBABLE CAUSES AND REMEDIES
C. MACHINE WILL NOT BUILD UP FULL
DISCHARGE PRESSURE
1. Air demand too great. Repair system air
leaks. Add compressor capacity to satisfy
demand.
2. Dirty air filter. Change or clean element if
required.
3. Control pressure regulator out of
adjustment. Adjust regulator.
4. Defective control regulator. Check
diaphragm and replace if necessary.
5. Blowdown valve open. Repair or replace.
6. Micro processor control setting off. See 6.5
for adjustment procedure.
Summary of Contents for 125G
Page 12: ...______________________________SULLIVAN PALATEK 12 CONTROL SCHEMATIC ...
Page 18: ...______________________________SULLIVAN PALATEK 18 4 5b WIRING DIAGRAM Y DELTA START OPTIONAL ...
Page 28: ...______________________________SULLIVAN PALATEK 28 PARTS LISTING ...
Page 31: ...SULLIVAN PALATEK______________________________ 31 DRIVE AND BASE ASSEMBLY ...
Page 32: ...______________________________SULLIVAN PALATEK 32 7 3 DRIVE AND BASE ASSEMBLY PARTS LIST ...
Page 33: ...SULLIVAN PALATEK______________________________ 33 LUBRICATION AND COOLING SYSTEM AIR COOLED ...
Page 37: ...SULLIVAN PALATEK______________________________ 37 LUBRICATION COOLING SYSTEM W C 200 250 ...
Page 38: ...______________________________SULLIVAN PALATEK 38 7 5b LUBRICATION COOLING SYSTEM W C 200 250 ...
Page 39: ...SULLIVAN PALATEK______________________________ 39 INLET AND CAPACITY CONTROL SYSTEM ...
Page 41: ...SULLIVAN PALATEK______________________________ 41 DISCHARGE SYSTEM 125 150 HP ...
Page 43: ...SULLIVAN PALATEK______________________________ 43 DISCHARGE SYSTEM 200 250 HP ...
Page 45: ...SULLIVAN PALATEK______________________________ 45 OPEN COMPRESSOR ELECTRICAL CONTROL PARTS ...
Page 47: ...SULLIVAN PALATEK______________________________ 47 ENCLOSED COMPRESSOR CONTROL PARTS ...
Page 48: ...______________________________SULLIVAN PALATEK 48 7 8b ENCLOSED COMPRESSOR CONTROL PARTS ...
Page 49: ...SULLIVAN PALATEK______________________________ 49 AIR COOLED ENCLOSURE 125 250 ...
Page 50: ...______________________________SULLIVAN PALATEK 50 7 10a AIR COOLED ENCLOSURE 125 150 ...
Page 51: ...SULLIVAN PALATEK______________________________ 51 AIR COOLED ENCLOSURE 200 250 ...
Page 52: ...______________________________SULLIVAN PALATEK 52 7 10b AIR COOLED ENCLOSURE 200 250 ...
Page 53: ...SULLIVAN PALATEK______________________________ 53 WATER COOLED ENCLOSURE ...
Page 54: ...______________________________SULLIVAN PALATEK 54 7 11 WATER COOLED ENCLOSURE ...
Page 56: ...______________________________SULLIVAN PALATEK 56 7 12b DECAL AND IDENTIFICATION ...