SECTION 2
S
HOP
T
EK
™
USER MANUAL
15
02250180-090 R00
S
TART
M
ODE
- 0
TO
50
PSIG
(0
TO
3.5
BAR
)
There is no load on the compressor at startup, the
solenoid valve is open and the inlet valve is closed.
When the compressor
(START) pad is pressed,
the separator tube pressure rises from 0 to 50 psig (0
- 3.4 bar). When it reaches its full operating speed
(maximum rpm), the compressor switches to the Full
Load Mode.
F
ULL
L
OAD
M
ODE
- 50
TO
127
PSIG
(3.4
TO
8.8
BAR
)
When the compressed air pressure rises above 50
psig (3.4 bar), the minimum pressure valve opens
allowing compressed air to flow into the service line.
From this point on, the Controller continuously
monitors the line air pressure. The solenoid valve
remains closed in this mode. As long as the
compressor is running at 127 psig (8.8 bar) or lower,
the inlet valve is fully open.
U
NLOAD
M
ODE
- G
REATER
THAN
127
PSIG
(8.8
BAR
)
When there is no, or only a small demand, the
Other pressure settings can be selected depending
on compressor application or rating.
Figure 2-5: Control System, ST400, ST500, ST700, 5-10 HP
1. Air Outlet
5. Separator Tube
2. Unload Solenoid Valve
6. Pressure Transducer
3. Air Inlet
7. Controller
4. Minimum Pressure/Check Valve
8. Check Valve
Summary of Contents for ShopTek ST1100
Page 10: ...NOTES 8...
Page 22: ...NOTES 20 02250180 090 R00...
Page 39: ...NOTES 37 02250180 090 R00...
Page 58: ...NOTES 56 02250180 090 R00...
Page 71: ...NOTES 69...