FILTERS AND MOISTURE SEPARATORS
SECTION 3
40
3.4
SAFETY INFORMATION
3.5
INSTALLATION
1. To get optimum performance there must be a
suitable connection that fits the inlet and out-
let piping.
2. Cut the air supply and discharge remainder
of air.
3. Adjust the condensate separator height with
respect to other component parts of system.
4. The condensate separator must always be
mounted in a vertical position.
5. Connect the housing to the system. Pay
attention to the arrow direction,which indi-
cates airflow outlet.
6. Check the condensate separator body mak-
ing sure that it is connected properly.
7. Connect the system to the air supply and
then check the condensate separator under
pressure.
3.5.1 T
YPICAL
I
NSTALLATION
S
ETUPS
WARNING
Disconnect or depressurize compressed air
line prior to any installation or maintenance
activity. Eye protection goggles or safety
glasses are always recommended
during installation and maintenance.
NOTE
See Common System Configurations as
shown in
on page 16 of typical
setups and filter applications. See “Repair
Parts Lists” for replacement
parts available.
NOTE
F-R-L – Point of use Filtration,
Regulation, and Lubrication as needed.
Summary of Contents for FH Series
Page 10: ...NOTES 10 ...
Page 31: ...31 NOTES ...
Page 32: ...FILTERS AND MOISTURE SEPARATORS SECTION 2 32 2 13 REPRESENTATIVE FILTER FX MODEL 02250193 459 ...
Page 34: ...FILTERS AND MOISTURE SEPARATORS SECTION 2 34 2 14 REPRESENTATIVE FILTER FW MODEL 02250194 578 ...
Page 36: ...FILTERS AND MOISTURE SEPARATORS SECTION 2 36 2 15 REPRESENTATIVE FILTER FH MODEL ...
Page 38: ...38 NOTES ...
Page 46: ...46 NOTES ...
Page 47: ...NOTES 47 ...