SubSurface Instruments AquaTrac User Manual Download Page 9

www.ssilocators.com

09

o

peration

The Aqua Trac™ resets its audio to "Medium" every time the unit is turned off. When starting a new detection job, set the 
volume to a comfortable level by increasing or decreasing the volume with the UP and Down arrows on the Keypad. Use 
the Volume Indicator on the screen as a reference to determine your most comfortable volume level.

After connecting the sensor/microphone and headphones, adjust 
the volume of your unit, place the Sensor/Microphone over the 
pipe or surface where a water leak is suspected. Press the trigger 
to activate the sound on the headphones; as an alternative you 
can also press the MUTE Button on the center of the keypad.

Listen on the same spot until you acquire a constant result.

Every time the OK button is pressed you should hear sound through the headphones.

When you have the trigger pressed and you move from one location to another, you'll hear interference and uneven sounds 
and bangs in your headphones.

When you are listening in an specific spot you should hear a uniform background sound.

The sounds picked up by the microphone will be increased or decreased by the type of filter you have your unit set to at 
the time of detection and also by how much traffic and activity is around you at the time of the detection. Noisy construction 
environments can be a little challenging to make a successful detection.

You might have to use the unit during evening hours or at a time of less outside noises for better results.

a

djusting

 

the

 

Volume

l

istening

 

With

 

the

 a

Qua

 t

raC

W

hat

 

sound

 

are

 

you

 

expeCted

 

to

 

hear

?

Increase Volume

Mute Button

Decrease Volume

Volume Indicator

MUTE Indicator

Summary of Contents for AquaTrac

Page 1: ...Instructions Functions and Warranty Information User Manual Water Leak Detector TM Scan for Digital Version...

Page 2: ...ts reserved No part of this manual may be reproduced copied modified or adapted without the prior written consent of the SubSurface Instruments Inc Please contact SubSurface Instruments Inc to request...

Page 3: ...Volume 09 Listening with the Leak Detector 09 What Sounds Should I Heard 09 Accessing Filters 10 Setting Custom Filters 10 Selecting the Correct Filter 10 Selecting Predefined Filters 11 Affecting Fa...

Page 4: ...It is essential that the manual is available for the trained operator to use as a reference You must read this manual carefully Do not drop the device the electronic components might get damaged with...

Page 5: ...of delivery against defects in material and workmanship We will repair or replace products that prove to be defective during warranty period By registering your unit online at http www ssilocators com...

Page 6: ...warranty NEVER open the housing of the unit this will also automatically void the warranty The unit leaves our facility in the original factory configuration no need for calibration or special setting...

Page 7: ...ic LCD back lit Display graphic indication of the selected filter sensitivity and battery charge Geophone Sensor Piezo electronic sensor high sensitivity and resistance with protection against wind an...

Page 8: ...to get your Aqua Trac ready for use in the field Connect the Ground Microphone to the unit and secure the connection by tightening the threaded washer If you need to use the extension rod thread it to...

Page 9: ...onstant result Every time the OK button is pressed you should hear sound through the headphones When you have the trigger pressed and you move from one location to another you ll hear interference and...

Page 10: ...tomatically the Aqua Trac will make the necessary calculations locking in the selected filter The selection of the appropriate filter depends on different factors such as pipe material depth of the ut...

Page 11: ...network using a manometer the minimum pressure required with this equipment is 55 psi plastic pipes and 20 psi metal pipes because you won t be able to hear any distinctive sound from a water leak wit...

Page 12: ...are The level of sensitivity of the equipment The equipment has 3 levels Low Medium and High it is recommended to keep this setting on medium in order to optimize the use of the equipment The language...

Page 13: ...ents Inc Attn Service Department 1230 Flightway Dr De Pere WI 54115 USA We will repair and ship the instrument back or advise you if the instrument is irreparable Note There is a minimum charge for re...

Page 14: ...hard padded case for shock and weather protection Includes The Aqua Trac Amplifier Electronic sensor with 5 1 5m of cable Headphones with 3 5mm jack Collapsible contact rod 3 pieces Magnet Li Ion batt...

Page 15: ...www ssilocators com 15 What s Included Hard IP68 Certified ABS customcarrying case included Sensor Microphone Collapsible Contact Rod Magnet Headphones Amplifier...

Page 16: ...very object that other locators can t find SSI features a vast line of professional underground and underwater locator products for every need including surveying construction ordnance removal excavat...

Reviews: