background image

17

EN

GB

GB

GB

GB

GB

GB

GB

GB

GB

GB

GB

GB

GB

GB

GB

The following procedures should be followed prior to storage of your generator for periods of 6 months or longer.

Drain fuel from fuel tank carefully by disconnecting the fuel line. 
Gasoline left in the fuel tank will eventually deteriorate making engine-starting difficult. 

Remove the drain screw of the carburetor.(See Fig. 

6

-

q

)

q

DRAIN SCREW

Change engine oil. 

Check for loose bolts and screws, tighten them if necessary. 

Clean generator thoroughly with oiled cloth. Spray with preservative if available. NEVER USE WATER
TO CLEAN GENERATOR ! 

Pull starter handle until resistance is felt, leaving handle in that position. 

Store generator in a well ventilated, low humidity area.

When generator engine fails to start after several attempts, or if no electricity is available at the output
socket, check the following chart. If your generator still fails to start or generate electricity, contact your
nearest Robin dealer or service shop for further information or corrective procedures.

12. TROUBLESHOOTING

11. PREPARATION FOR STORAGE (See Fig. 

6

6

)

Check if engine switch is in its proper position.

Turn engine switch to "       "(CHOKE) position.

When Engine Fails to Start:

When No Electricity Is Generated at Receptacle:

Check if the DC circuit breaker 
is turned OFF.

Check if the "O_Lod"(overload) is indicated 
in the Multi Monitor.

Check AC receptacle and DC terminals for 
loose connection.

Check to see if engine starting was 
attempted with appliances already 
connected to generator.

Depress the circuit breaker into 

"  I  "(ON) 

position, after making sure the charging 
current level is proper and the battery is in 
the normal condition.

Stop the engine and check the appliance 
and/or generator for overloading. 

Secure connection if necessary.

Turn off switch on the appliance, and 
disconnect cable from receptacle. Reconnect 
after generator has been started properly.

Check fuel level.

Check to make sure generator is not 
connected to an appliance.

Check spark plug for loose spark plug cap.

Check spark plug for contamination.

Check engine oil level.

Check if the recommended spark plug 
would be adopted.

If empty, refill fuel tank making sure not to overfill.

If connected, turn off the power switch on the 
connected appliance and unplug.

If loose, push spark plug cap back into place.

Remove spark plug and clean electrode.

If the engine oil level is low, add the oil to the 
upper level line on the oil gauge.

If not, replace with the recommended spark plug.
If the recommended spark plug is not available 
by all means, make sure to replace with 
equivalent one of resistance type.

RG4300iS en̲GU7045  10.6.8  4:35 PM  ページ17

Summary of Contents for RG3200iS

Page 1: ...ISSUE EMD GU7130 RU 3ZZ9990551 PRINTED IN JAPAN January 2011 Original ...

Page 2: ...a partir del motor y que se observan bien los reglamentos locales appendix Istruzioni per lo smaltimento Per lo smaltimento di questo prodotto assicurarsi di aspirare il carburante e l olio dal motore in conformità con le regolamentazioni locali apêndice Instruções para tratamento como resíduo Quando eliminar este produto assegure se de que o combustível e o óleo são escoados do motor e sujeitos à...

Page 3: ...3 4 5 6 2 3 4 2 1 3 6 1 1 1 2 1 2 1 1 1 2 RG4300iS en GU7045 10 6 8 4 35 PM ページ02 ...

Page 4: ......

Page 5: ......

Page 6: ...EN LWA WARNING WARNING NO FIRE IN RAIN OR SNOW DO NOT OPERATE DO NOT CONNECT TO A HOUSEHOLD CIRCUIT UNLEADED GASOLINE RG4300iS en GU7045 10 6 8 4 35 PM ページ05 ...

Page 7: ...our products certain procedures and specifications are subject to change without notice When ordering spare parts always give us the MODEL PRODUCTION NUMBER PROD No and SERIAL NUMBER SER No of your Product Please fill in the following blanks after checking the production number on your product Location of label is different depending on the product model CONTENTS 1 SAFETY PRECAUTIONS 2 2 COMPONENT...

Page 8: ...case piston seizure may occur even if the oil is above the upper level WARNING Pay attention to the wiring or extension cords from the generator to the connected device If the wire is under the generator or in contact with a vibrating part it may break and possibly cause a fire generator burnout or electric shock hazard Replace damaged or worn cords immediately WARNING Do not operate the generator...

Page 9: ...g Do not pour water directly over the generator nor wash it with water WARNING Be extremely careful that all necessary electrical grounding procedures are followed during each and every use Failure to do so can be fatal WARNING It is absolutely essential that you know the safe and proper use of the power tool or appliance that you intend to use All operators must read understand and follow the too...

Page 10: ...4 EN GB GB GB GB GB GB GB GB GB GB GB GB GB GB GB RG4300iS en GU7045 10 6 8 4 35 PM ページ4 ...

Page 11: ...LEVEL w LOWER LEVEL Change oil if contaminated See How To Maintenance 2 CHECK ENGINE FUEL See Fig 2 2 e e r r Check fuel level at fuel level gauge See Fig 2 r q EMPTY E w FULL F e LEVEL MARK r FUEL LEVEL LINE If fuel level is low refill with unleaded automotive gasoline Be sure to use the fuel filter screen on the fuel filter neck See Fig 2 e q FUEL FILTER SCREEN w TANK CAP Recommended engine oil ...

Page 12: ...or which has been already grounded to the earth See Fig 2 t q GROUNDING SPIKE If such grounding conductor or grounding electrode is unavailable connect the grounding lug of the generator to the grounding terminal of the using electric tool or appliance See Fig 2 y q GROUND TERMINAL 6 NOTES ON INSTALLATION Always be sure to place the generator on a level surface locking the wheel with the stopper a...

Page 13: ... q RECOIL STARTER HANDLE w PULL BRISKLY d After starting allow the starter handle to return to its original position with the handle still in your hand e Electric starter model Insert the key into the key switch and turn it clockwise to the ON position to start the engine Then turn the key further to the START position The engine will be started by starting motor Do not connect defective appliance...

Page 14: ... w Operation hour lamp Lamp red is turned on when changing over into operation hour indication in the LE display e e Voltage lamp Lamp red is turned on when changing over into voltage indication in the LE display r r Frequency lamp Lamp red is turned on when changing over into frequency indication in the LE display t t LE display changeover switch When depressing this switch indication in LE displ...

Page 15: ... resume displaying in the normal manner 2 AC APPLICATION a Make sure the voltage indicated in the LE display is the normal level approx 230V This generator is thoroughly tested and adjusted in the factory If the generator does not produce the specified voltage consult your nearest Robin dealer or service shop b Turn off the switch es of the electrical appliance s before connecting to the generator...

Page 16: ...n page 5 and restart the engine c If the engine does not start by usual starting procedures check the oil level Do not remove OIL SENSOR PROBE when refilling with oil Remove oil filler cap on the opposite side of carburetor CAUTION Some appliances need a surge of energy when starting This means that the amount of electrical power needed to start the appliance may exceed the amount needed to mainta...

Page 17: ...Nominal cross section A W G Allowable current No of strands strands dia Resistance Current Amp No mm Ω 100m mm2 No A 1A 3A 5A 8A 10A 12A 15A 0 75 18 7 30 0 18 2 477 2 5V 8V 12 5V Voltage drop 1 27 16 12 50 0 16 1 486 1 5V 5V 7 5V 12V 15V 18V 2 0 14 17 37 0 26 0 952 1V 3V 5V 8V 10V 12V 15V 3 5 12 to 10 23 45 0 32 0 517 1 5V 2 5V 4V 5V 6 5V 7 5V 5 5 10 to 8 35 70 0 32 0 332 1V 2V 2 5V 3 5V 4V 5V VOL...

Page 18: ...d cleaner element Clean and adjust carburetor valve clearance and valve seat along with cylinder head EVERY 1 000 HOURS 24 MONTHS Inspect control panel parts Check rotor and starter Replace engine mount rubber Overhaul engine Change fuel lines NOTE Initial oil change should be performed after first twenty 20 hours of use Thereafter change oil every 100 hours Before changing the oil check for a sui...

Page 19: ...and tighten with the butterfly nuts Push the lead acid battery all the way inward 7 HOW TO MAINTENANCE See Fig 5 5 2 ENGINE OIL CHANGE See Fig 5 5 w w 1 SIDE PANEL L R See Fig 5 5 q q Change engine oil every 50 hours For new engine change oil after 20 hours a Drain oil by removing the drain plug and the oil filler cap while the engine is warm q OIL DRAIN PLUG b Reinstall the drain plug and fill th...

Page 20: ...cable to the negative terminal Red cable to the positive terminal Black cable to the negative terminal Should the connection be made in incorrect manner the engine will be broken CAUTION RED CABEL RED CABEL 5 LESS THAN 131 mm RG2800iS 3200iS 162 mm RG4300iS LESS THAN 114 mm RG2800iS 3200iS 136 mm RG4300iS LESS THAN 71 mm RG2800iS 3200iS 82 mm RG4300iS 1 2 3 4 5 1 6 2 3 4 Battery Base Flange Bolt S...

Page 21: ...the engine is stopped before starting any maintenance servicing or repair Please adjust the key switch to the stop position It might be short for driving and the start position and dangerous Please exchange it for the fuse of specified capacity It leads to the breakdown when fuses other than specification are used Please never use the wire and the copper wire etc instead of the fuse It causes over...

Page 22: ...lamp turned on properly The engine switch normally operated No leakage of engine oil and fuel gasoline When transporting the generator make sure that the fuel gasoline should be drained from the tank a Turn the engine switch to the CLOSE position b Drain the fuel from the tank To prevent fuel spillage due to the vibration and impact never transport the generator with the fuel gasoline filled in th...

Page 23: ...ctricity Is Generated at Receptacle Check if the DC circuit breaker is turned OFF Check if the O_Lod overload is indicated in the Multi Monitor Check AC receptacle and DC terminals for loose connection Check to see if engine starting was attempted with appliances already connected to generator Depress the circuit breaker into I ON position after making sure the charging current level is proper and...

Page 24: ...e Breaker Engine Model EX17 Type Forced air cooled 4 cycle OHC Gasoline Engine Displacement mL 169 Fuel Automotive Unleaded Gasoline Fuel tank capacity L 10 8 Rated continuous operation Approx hours Starting system Recoil Dimension Length mm 537 Width mm 482 High mm 583 Dry weight kg 54 EX27 EX21 74 59 RG4300iS RG3200iS Electronic Breaker 4 3 3 8 3 2 2 8 265 211 580 527 618 AC DC 7 6 12 8 5 3 6 5 ...

Page 25: ... R Brn Brn R R R W R W R R W W W R W W W W W W W Y Y Grn Y Grn Y Grn Y Grn Y Grn Y Grn Y Blk Blk Blk Blk Blu Blu Blu Blu Blu W Blu Blu Blu Y Blu Grn Grn Gry Gry Gry Pur AC receptacle 230V AC receptacle 230V GENERATOR CONTROL PANEL ENGINE Coil 3 Coil 2 Coil 1 Spark plug Cover With Plastic tepe R W Blk Black Wiring color cord Blu Blue Brn Brown Grn Green Org Orange Gry Gray R Red W White Y Yellow Gr...

Page 26: ...nsor DC circuit breaker DC output terminal Org Org Org Org Org Brn Brn Brn Brn Brn R R W W W W W W W W Y Y Grn Y Grn Y Grn Y Grn Y Blk Blk Blk Blk Blk Blu Blu Blu Blu Blu W W Blu Blu Blu Y Blu Grn Grn Gry Gry Gry Pur GENERATOR CONTROL PANEL ENGINE Coil 3 Coil 2 Coil 1 Spark plug Cover With Plastic tepe R Blk Battery Starting motor Key switch M M B ST L IG REGULATOR R Y Y Grn Y Fuse R W Grn Y AC re...

Page 27: ...a partir del motor y que se observan bien los reglamentos locales appendix Istruzioni per lo smaltimento Per lo smaltimento di questo prodotto assicurarsi di aspirare il carburante e l olio dal motore in conformità con le regolamentazioni locali apêndice Instruções para tratamento como resíduo Quando eliminar este produto assegure se de que o combustível e o óleo são escoados do motor e sujeitos à...

Page 28: ...ISSUE EMD GU7130 RU 3ZZ9990551 PRINTED IN JAPAN January 2011 Original ...