Integrated Refrigeration Design Guide
Page 1: ...Integrated Refrigeration Design Guide...
Page 2: ...notice Visit subzero com specs for the most up to date information IMPORTANT NOTE Throughout this guide dimensions may vary by 1 8 3 Dimensions in parentheses are millimeters unless otherwise specifi...
Page 3: ...ualified Star K certified Integrated Refrigeration With custom front panels and hardware Sub Zero invented integrated columns tall and drawer models that disappear into the decor Integrated units fit...
Page 4: ...ALL R CU FT L F CU FT L IT 30R ID 16 5 467 IT 30FI 15 1 428 IT 30CI ID 10 6 300 5 0 142 IT 36R ID 20 5 580 IT 36CI ID 13 3 377 6 4 181 DRAWER R CU FT L F CU FT L ID 24R 4 0 113 ID 24F I 3 8 108 ID 27R...
Page 5: ...2 2146 MAX 3 8 10 A B 13 4 45 W 173 4 451 24 610 1 4 6 341 2 876 109 16 268 135 16 338 3 8 10 35 8 92 34 864 MIN TO 35 889 MAX TALL MODEL W A B IT 30R ID IT 30FI 30 762 55 8 143 281 2 724 IT 30CI ID 3...
Page 6: ...thickness when planning the finished opening depth Approximately 31 2 89 of the opening depth may be visible when the door drawers are open and should be finished to match cabinetry Refer to the illus...
Page 7: ...DE OF OPENING Electrical supply location Plumbing The water supply line should be located within the shaded area shown in the illustration below The water supply line should be connected to the house...
Page 8: ...o handles are avail able through an authorized Sub Zero dealer For local dealer information visit the find a showroom section of our website subzero com PANEL REQUIREMENTS PANEL WEIGHT MAX 18 Column 4...
Page 9: ...toe kick area can extend beyond the typical toe kick height provided it does not exceed the dimensions in the illustration below 24 610 TO BACK OF UNIT VENTED LOUVERS HINGE DOOR PANEL 11 8 29 MAX TOE...
Page 10: ...length and stud spacing of standard handles for integrated models STANDARD HANDLES COLUMN LENGTH STUD SPACING Tubular 501 8 1273 471 8 1197 Pro 483 8 1229 471 8 1197 TALL DOOR 36 DRAWER LENGTH STUD S...
Page 11: ...NETRY DOOR OPEN MAXIMUM 105 POTENTIAL INTERFERENCE 1 8 3 REVEAL 3 4 19 PANEL 1 25 0 SCALE Maximum door opening top view Maximum Door Opening FULL SCALE TEMPLATE As the panel width and or depth increas...
Page 12: ...r must contact Sub Zero Inc using the information below to receive repaired or replacement parts Sub Zero will not reimburse the owner for parts purchased from non certified service or other sources T...
Page 13: ...istered trade marks and service marks of Sub Zero Inc Wolf Wolf Design Wolf Gourmet W Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance Inc col...
Page 14: ...SUB ZERO INC P O BOX 44848 MADISON WI 53744 SUBZERO COM 800 222 7820 SZINIP2DG 9 2013...