7 Teleservice Application Framework
User Manual
108/374
will not be started!
usr_cmd_file Result
Section: TC1 device name
# Client_ID: Optional <hostname> will be set by the yserverd, e.g. TC1-<serial_num>_0...n
# Min. client id length is 1, max. client id length is 512, default client name is the TC1
hostname
# If no client name is set, default will be set (hostname).
client_id 101011421008
Section: Default interval for Nextjob.job checking
# Trigger interval for the NextJob.job file sets the connection_cycle_timeout, be
overwritten by the interval of the NextJob.job file,
# in case there is one set.
# Min. timeout is 0s, max. timeout is 0xFFFFFFFFs
# If no timeout is set, an error message will be put on stdout. Specific connection will
not be started!
connection_cycle_timeout 360
Section: Data logger transmission size
# This section sets the maximum data logger transmission size in bytes before the '.end'
file is created.
# The default value is 0, this means that the '.end' file is created after the complete
transmission of the data logger file.
# Min. and default size is 0, max. size is 0xFFFFFFFF
# If no size is set, the default value will be set.
DLTS 0
Section: Maximum result file size
# Sets the maximum size in bytes for one single result file.
# After reaching the max. size of a result file, a new one is created --> result.001,
result.002 ...
# Min. size is 0, max. size is 0xFFFFFFFF
# The size will be set to 4096, if value of the size is less than 4096.
# If no size will be set, 8192 will be set.
max_result_file_size 8192
NOTE:
For more information about the NextJob.job mechanism contact the Sensor-Technik Wiedemann
GmbH support.
Summary of Contents for TC1
Page 1: ...TC1 User Manual Version of this document V1 00r0 ...
Page 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Page 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Page 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Page 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...