5.16 Special Operating Modes
AutoTouchPlus offers a series of special operating modes and features to ac-
commodate specific production requirements and working styles.
5.16.1 Stop Frame Automation
The Stop Frame automation feature makes it possible to write specific control
values between timecode locations. The user can stop timecode playback at a
specific location, set any number of controls to desired values, and move to
the next location forward in time where values may again be adjusted. The
initially set values will be recorded between the timecode locations.
Stop Frame automation may also be used with the internal timecode generator
and
LOCATE
button when working with an EDL (Edit Decision List). This
allows automation data to be recorded in a ‘pseudo offline’ fashion without
the work media.
Stop Frame Automation may be enabled at any point. After control values
are written at a specific location, the media can be moved forward to the next
location, and the next set of values can be written. If locations are not known,
Stop Frame may be ‘suspended’ as the media is searched.
Stop Frame Controls
There are two buttons in the ACU window associated with Stop Frame auto-
mation.
The Stop Frame buttons perform the following functions:
•
STOP FRAME
: When engaged, all enabled controls will switch to their
active RECORD state. The values of these controls will be recorded at
the current timecode location. If timecode is advanced, these values will
be recorded to each consecutive location. At any time, the user may stop
timecode playback and make further adjustments to the controls. The new
values will be recorded at the current location and any consecutive ones
if the media is moved forward. It is important to note that control values
will not be recorded if the timecode is moved backward.
•
SUSPEND
: When engaged, Stop Frame recording is suspended. This allows
timecode to be moved backward or forward so a the next timecode loca-
tion may be found. No control values will be written while
SUSPEND
is
engaged.
Summary of Contents for Vista 5 M3
Page 18: ...Vista 5 M3 Digital Mixing System 1 2 Introduction Document generated 28 08 13 SW V4 9 ...
Page 40: ...Vista 5 M3 Digital Mixing System 1 24 Introduction Document generated 28 08 13 SW V4 9 ...
Page 90: ...Vista 5 M3 Digital Mixing System 3 2 Parameters Document generated 28 08 13 SW V4 9 ...
Page 144: ...Vista 5 M3 Digital Mixing System 3 56 Parameters Document generated 28 08 13 SW V4 9 ...
Page 300: ...Vista 5 M3 Digital Mixing System 5 4 AutoTouchPlus Document generated 28 08 13 SW V4 9 ...
Page 348: ...Vista 5 M3 Digital Mixing System 5 52 AutoTouchPlus Document generated 28 08 13 SW V4 9 ...
Page 506: ...Vista 5 M3 Digital Mixing System 7 2 DAW Control Document generated 28 08 13 SW V4 9 ...
Page 516: ...Vista 5 M3 Digital Mixing System 7 12 DAW Control Document generated 28 08 13 SW V4 9 ...
Page 518: ...Vista 5 M3 Digital Mixing System 8 2 RELINK Document generated 28 08 13 SW V4 9 ...