SBM-01 high precision battery monitor
17
replace your batteries with the exact same brand and type, it is only
necessary to reset the History Data and leave the Functions unchanged.
To activate the Reset menu, press the SETUP key for eight seconds.
After eight seconds a flashing “rSt.F” (“Reset Functions”) appears on the
display. To change the value to “On” or “OFF,” press the < and > keys.
By pressing the SETUP (next) key, “rSt.H” (“Reset History”) can be
selected. Again, to change the value to “On” or “OFF,” press the < and >
keys. To apply the actual reset of whichever item is set to “On,” press the
SETUP key for three seconds until the display stops flashing and the
battery monitor jumps back to normal operation mode again.
When the monitor is secured by the Super-lock, the Functions and
History Data cannot be reset and “S.Loc” will appear on the display after
pressing the < or the > key. If the SBM-01 operates in the Reset menu
and no keys are pressed for 90 seconds, the monitor will jump back to
normal operating mode automatically, without resetting the
Functions and/or History Data.
4.3 PC-link
Each SBM-01 offers the possibility to communicate with a Personal
Computer. However, the optional external communications interface kit is
required for this feature. This communications interface only needs to be
connected when actually communicating with the SBM-01, to avoid
unnecessary power consumption. With the dedicated SBM-01 Windows
95/98/Me/2k/XP
®
software, the user can simultaneously display all
parameters. The SBM-01 can also be fully programmed via this link,
while the complete Function setup can be saved to disk. Furthermore
history data can be readout, the SBM-01 can be tested and the super-
lock can be (de-)activated.
4.4 Super-lock
With the super-lock feature, the setup menu of the SBM-01 can be
completely locked and secured by a password. In super-lock mode the
history data cannot be erased. The normal operating mode is not
affected by the super-lock and the Functions in the setup menu can be
reviewed, but not altered. Only the user/installer knowing the password,
can unlock the SBM-01 via the PC-link.