Service Manual
-
Power Protection
Monitoring
Diesel Control
Power Management
SYMAP
®
Page 1: ...Service Manual Power Protection Monitoring Diesel Control Power Management SYMAP...
Page 2: ...PROSECUTION THE CONTENT OF THIS MANUAL IS FURNISHED FOR INFORMATIONAL USE ONLY THE CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY STUCKE ELEKTRONIK GMBH STU...
Page 3: ...or 68 2 10 6 Power factor controller 71 2 10 7 Big consumer request BCR 73 2 10 8 Blackout 76 2 10 9 Engine control 80 2 10 10 Starting phase 83 2 10 11 Stopping phase 86 2 10 12 Preferential trip lim...
Page 4: ...ector surge dF dt supervision relay 158 3 25 ANSI 78 S Out of step tripping 160 3 26 ANSI 79 AC reclosing relay 163 3 27 ANSI 81 Frequency relay 166 3 28 ANSI 81 B BUS frequency relay 169 3 29 ANSI 86...
Page 5: ...lfilled e g a limit is reached otherwise inactive logically False The event sinks are linked to fixed processes or fixed functions and can be programmed by the user The user can build a link between t...
Page 6: ...ER MENU ENTER MENU ENTER MENU Overview Current meters Voltage meters Power meters Counter Ground values Harmonic waves Frequency meters Analog inputs Display setting Active alarms Alarm groups Active...
Page 7: ...MENU EXIT APPLIC ANWENDUNGEN F2 ALARMS VERSION none VERSION 6 SCHALTER Betrieb LOCAL Prozess AUTO Zustand ENTRIEG Recloser AUS SYSTEM Pieper AUS Heizer EIN LOCKOUT Zustand ZU L schen Betrieb SCHALTER...
Page 8: ...rs ALARM CHANNEL SELECT ALARM CHANNEL EVENT Select 01 1 line editierbarer Text 2 line editierbarer Text mode NO ACK trigger 1505 block by 0 delay 0 0 sec 1 group 83 1 group none priority none option n...
Page 9: ...e editierbarer Text mode NO ACK trigger 1505 block by 0 delay 0 0 sec 1 group 83 1 group none priority none option none beeper OFF Select ALARM TRIP red amber green LED CONTROL ALARM CHANNEL EVENT Sel...
Page 10: ...ATUS DATA Testbox I O DATA SSC Transferstatus DATA SSC MU RU Data DATA CAN Transferstatus DATA Serial channel DATA Transponder DATA EEPROM status DATA EXT boards ADCs DATA Software DATA Relais driver...
Page 11: ...he different system parameter groups Figure 2 1 System parameter groups SYSTEM PARAMETER 00 Codes 01 General parameter 02 Nominal ratio values 03 Communication 04 Analogous inputs 05 Binary inputs 06...
Page 12: ...s but without codes and event builder 0003 Master password Access without restrictions NOTE The default codes have all the value 1111 The passwords can be disabled by setting all 3 passwords parameter...
Page 13: ...IN OUT control event 0121 EARTH ON feedback 0 0122 EARTH OFF feedback 0 0123 EARTH OFF ctrl event Setting range OFF ON 0 9999 Event 0 9999 Event event display only event display only 0 9999 Event 0 99...
Page 14: ...39 BREAKER 3 ON feedback 0 0140 OFF feedback 0 0141 ON OFF control event 0142 OFF ON control event 0143 IN feedback 0 0144 OUT feedback 0 0145 OUT IN control event 0146 IN OUT control event 0147 EARTH...
Page 15: ...pulse 0 0177 pulse duration 0 00 sec 0178 Q kvarh pulse 0 0179 pulse duration 0 00 sec 2480 Block ACK key by event 0 ev 2481 Switch OFF LCD LEDs by 0 ev 2482 Working hours limit 1 0 h 2483 Working ho...
Page 16: ...is valid both for all meter values displayed on all pages and on the 7 segment displays and for those into communication transferred measured values This parameter does not affect the measured values...
Page 17: ...Breaker control and Interlock diagrams see chapter 2 9 0125 ctrl time fail ev Setting of supervision time control time of the maximum operation time of a switching cycle or position movement of break...
Page 18: ...cycles of earthing switch no 1 before next inspection 0165 Breaker 2 ON max cyc Setting of maximum cycles of disconnecting switch no 2 before next inspection 0166 EARTH max cyc Setting of maximum cyc...
Page 19: ...0178 Q kvarh pulse Setting of kvarh reactive power inductive per counter pulse zero means deactive 0179 pulse duration Setting of the pulse duration use the event 0179 to drive a binary output 2480 Bl...
Page 20: ...minal input 110Vac 0223 Shunt 2 nominal input 110Vac 0224 CT DIFF2 primary side 0 A BACK EXIT Setting range 0 65535 V 0 999999 V 0 65535 V 0 65535 A 0 65535 A 0 65535 A 0 65535 A 0 65535 A 0 01 99 99...