![STUCCHI MULTISYSTEM Series Instructions Manual Download Page 7](http://html1.mh-extra.com/html/stucchi/multisystem-series/multisystem-series_instructions-manual_1386414007.webp)
The luminaire can be fastened to the adapter using following accessories: S-9519/5 (Pic. 9) + S-
9519/M8 or S-9519/M10 (Pic. 10). If series 9529…M adapters are used, two rotation kits and two
nipple kits must be ordered. First place the special washer inside the plastic body of the
rotation kit, followed by S-9519/M10 or S-9519/M8 nipple (Pic. 11). Next, tighten screw B lightly
so that the washer and nipple are held in place inside their plastic housing (Pic. 12). Loosen
the two screws C1-C2 from the series 9519…M or 9529…M adapter and remove the cover;
insert the rotation kit, previously assembled with the washer and threaded nipple, by passing it
through the hole on the base of the adapter body. During assembly, screw D of the rotation kit
must be on the same side as hole F4 on the side wall of the adapter. Subsequently, screw the
rotation kit onto the adapter using the two screws E1-E2. After completing this operation, put
the cover on the adapter and tighten the two screws C1-C2 (Pic. 13) (when using polarised
versions, make sure that the cover is mounted in the proper direction). To increase or
decrease the friction of the adapter against the stem of the luminaire, tighten or loosen screw
D using an appropriate screwdriver (Pic. 14).
Adapter Rotation Kit and M10 or M8 Nipples