Stübbe MOT C2 Series Original Operating Manual Download Page 6

Transport, Storage and Disposal

4

Transport, Storage and
Disposal

4.1

Unpacking and inspection on delivery

1. Unpack the device when received and inspect it for trans-

port damage and completeness.

2. Check that the information on the type plate agrees with

the order/design data.

3. Report any transport damage to the manufacturer immedi-

ately.

4. If fitted immediately:

Dispose of packaging material

according to local regulations.

If fitted at a later point: leave device in its original pack-
aging.

4.2

Transportation

Device should preferably be transported in the original
packaging.

4.3

Storage

NOTE

Material damage due to inappropriate storage!

Store the device properly.

1. Make sure the storage room meets the following condi-

tions:

Dry

Frost-free

Vibration-free

Not in direct sunlight

Storage tempe10 °C to +60 °C

2. Device should preferably be stored in the original packag-

ing.

4.4

Disposal

Plastic parts can be contaminated by poisonous or radioac-
tive media to such an extent that cleaning will not be suffi-
cient.

WARNING

Risk of poisoning and environmental damage from
medium!

Use personal protective equipment when carrying out any
work on the device.
Prior to the disposal of the device: Neutralize residues of
medium in the device.

1. Remove electronic parts and dispose of in accordance with

local regulations.

2. Dispose of plastic parts in accordance with local regula-

tions.

6

MOT C2

BA-2020.11.16 US

302 352

Summary of Contents for MOT C2 Series

Page 1: ...020 11 16 US Print No 302 352 TR MA DE Rev001 ST BBE GmbH Co KG Hollwieser Stra e 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 E mail contact stuebbe com Internet www stuebbe co...

Page 2: ...3 Storage 6 4 4 Disposal 6 5 Installation and connection 7 5 1 Check operating conditions 7 5 2 Prepare tank 7 5 3 Install device 7 5 4 Electrical connection of device 7 6 Operation 8 6 1 Configure d...

Page 3: ...and the other applicable documents especially all safety instructions and warnings 1 2 Other applicable documents To download Resistance lists Resistance of materials used to chemicals www stuebbe co...

Page 4: ...otective equipment available Qualified personnel Make sure all personnel tasked with work on the device have read and understood this manual and all other appli cable documents especially the safety m...

Page 5: ...t output 3 2 Description The device measures the filling level of a liquid medium with the help of a magnetic float The device transmits the measured value via a standardized 4 20 mA current output 3...

Page 6: ...age due to inappropriate storage Store the device properly 1 Make sure the storage room meets the following condi tions Dry Frost free Vibration free Not in direct sunlight Storage temperature 10 C to...

Page 7: ...ar filling pipes When installing in open tanks or basins do not install the unit over turbulence or the vortex caused by agita tors 5 3 Install device Tank has been properly prepared Avoidance of medi...

Page 8: ...ted properly with the power supply and ready for operation Device is set manually as required For this purpose the current output for filling level must be displayed in the higher level controller as...

Page 9: ...rotective equipment when carrying out any work on the device Error Possible cause Corrective action Float is stuck Clean sensor No change to the output signal Sensor defective Inform ST BBE customer s...

Page 10: ...al data dimensions and accessories are described in the data sheet 1 2 Other applicable documents Page 3 9 2 Plug assignment 2 1 3 4 Fig 3 Connection diagram 1 4 20 mA signal 2 Not assigned 3 Not assi...

Reviews: