Stuart Turner 46638 Installation, Operation & Maintenance Instructions Manual Download Page 1

Installation, Operation & Maintenance 

Instructions

Please leave this instruction booklet with the home owner as it contains 

important guarantee, maintenance and safety information

Read this manual carefully before commencing installation.

This manual covers the following products:

Flood Kit

Pt. No. 46638

50 Hz

1

CE compliant product

STUART

Summary of Contents for 46638

Page 1: ...nstruction booklet with the home owner as it contains important guarantee maintenance and safety information Read this manual carefully before commencing installation This manual covers the following...

Page 2: ...f a low level cut out to prevent the risk of the pump running dry The pump is suitable for dirty water applications and is capable of handling semi solids in suspension of up to 5 mm in diameter STORA...

Page 3: ...understand the hazards involved z z Children shall not play with the appliance z z Cleaning and user maintenance shall not be made by children without supervision z z Maximum head closed valve 0 85 ba...

Page 4: ...the pump dry z z In the unlikely event of mechanical seal failure pollution of the liquid could occur due to the leakage of lubricants z z If the supply cord is damaged it must be replaced by Stuart...

Page 5: ...fitted 1 Elbow fitted 1 Crate all parts inside 1 Connector fitted 1 Lockable Lid fitted to crate 1 Lay flat hose 15 m fitted to pump 1 A E B Fig 1 IMPORTANT With the pump removed from its packaging ch...

Page 6: ...er entering the pump must be controlled as follows 1 11 The maximum allowable water temperature is 35 o C 1 12 The minimum allowable water temperature is 4 o C B General 1 13 This unit comes completel...

Page 7: ...itch operation section for further details 2 15 Setting up Set up unit as shown below 1 Open lid to access unit Fig 2 2 Uncoil and feed both the lay flat hose and the supply cable through the hole in...

Page 8: ...tically when the selection indicator is set to automatic It also provides a low level cut out to prevent dry running 2 19 Manual Operation Switch Position Up To start the pump lift the selector lever...

Page 9: ...Amp double pole switched socket outlet in compliance with BS 1363 2 The socket outlet should be mounted in an easily accessible position and should be labelled if confusion is possible to allow easy i...

Page 10: ...mmediately evident from pump outlet If it is not repeat step 4 12 4 14 For Further Technical Support Phone the Stuart Turner TechAssist team on 44 0 800 31 969 80 Our staff are trained to help and adv...

Page 11: ...t the filters are clean and free from debris which in turn ensures the pump will always run at maximum efficiency A blocked filter can cause damage to the pump 5 14 The pump must be cleaned as follows...

Page 12: ...dy DO NOT INVERT float housing 3 Fig 9 4 Note the position of the two floats 4 within the float housing 3 Fig 10 5 Remove and clean the floats 4 Fig 11 6 Clean the inside of the float housing 3 and th...

Page 13: ...with 15 m hose 83 l min zero head hose laid flat 80 l min 2 0 m head Minimum immersion depth Fully submerged Maximum immersion depth 7 metres Suction to remaining depth manual mode 3 6 mm Suction to r...

Page 14: ...all and connect cable Pump will not start Power not connected to the electricity supply Check the cable is connected correctly and power supply is switched on Check fuse Impeller Jammed Clean away deb...

Page 15: ...which have a negligible effect on the value or operation of the kit Reasonable evidence must be supplied that the product has been purchased within the guarantee term prior to the date of claim such...

Page 16: ...N 61000 3 2 BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 11 RoHs Directive 2011 65 EU IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC M...