background image

   

Test Report No.: GETEC-E3-06-043 

FCC Class B Certification 

 

EUT Type: 21” FLAT PANEL MONITOR 

 

 

APPENDIX G 

: USER’S MANUAL   

 

FCC ID: QVXAMM213TDS3

 

Summary of Contents for VisionElect 240-030-930

Page 1: ...Test Report No GETEC E3 06 043 FCC Class B Certification EUT Type 21 FLAT PANEL MONITOR APPENDIX G USER S MANUAL FCC ID QVXAMM213TDS3 ...

Page 2: ...2006 05 www stryker com 1000 400 895 A VISIONELECT 21 High Definition LCD Monitor REF 240 030 930 User Guide ...

Page 3: ...16 42 417 20 mm 19 21 488 mm 5 05 128 20 mm 3 94 100 mm 95 24 25 mm 3 15 80 mm 2 05 52 mm 8 66 220 mm 6 23 163 20 mm 3 94 100 mm 4 99 127 mm ...

Page 4: ...m Interconnection 8 Power Connection 8 Operating the Monitor 9 Front Panel Controls 9 Standard On Screen Display OSD Operation 10 Stryker Camera Preset Modes 10 OSD Function Description 11 Cleaning the Monitor 12 Troubleshooting 13 Technical Specifications 14 Classification and Approvals 17 Electromagnetic Compatibility 16 Warranty 22 Service and Claims 22 Declaration of Conformity 23 ...

Page 5: ...nt 5 Do not place the monitor or any other heavy object on the power cord Damage to the cable can cause fire or electric shock 6 Should any solid object or liquid fall into the panel unplug the unit and have it checked by qualified personnel before operating it any further 7 Unplug the unit if it is not to be used for an extended period of time To disconnect the cord pull it out by the plug Never ...

Page 6: ...nected to an equipment receptacle labeled Hospital Only or Hospital Grade 4 To connect to an international power supply use an attachment plug appropriate for the power outlet 5 Turn power off when unit is not in use 6 Remove the power module and connection when transporting the unit 7 Save the original carton and associated packing material They will be useful should you have to transport or ship...

Page 7: ...ency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation which can be determined by turning the equipment off and on the user is encourage to try to correct the interference by one or more of the following measures Reorient or reloc...

Page 8: ...n Economic Community Council directives and to harmonized standards published in the official journal of the European Communities Tested and certified by DEMKO in accordance with EN 60601 1 and EN 60601 1 2 51LJ Medical Equipment E215822 Medical Equipment is in accordance with UL 60601 1 and CAN CSA C22 2 No 601 1 in regards to electric shock fire hazards and mechanical hazards Tested to comply wi...

Page 9: ...cy mode the microprocessor based circuitry allows the monitor to function at the precision of a fixed frequency The resident memory allows for storing factory default settings and also additional user adjustment parameters The maximum resolution achievable is UXGA 1600 1200 be 60Hz st suited for Stryker cameras The monitor is compliant with the VESA DPMS power management standard In order to save ...

Page 10: ...ist to make sure all components have been included In addition to this manual you should find a 1 DVI cable b 1 VGA HDDB15 cable c 1 AC adapter Stryker P N 240 030 931 d 1 Hospital grade AC power cord e 4 M4 x 10mm VESA screws not shown f 1 BNC cable g 1 S Video cable h 1 15 or 75 extension cable with heat shrink tubing for connection to the DC power cord optional not shown i Power supply bracket ...

Page 11: ...88 Series 1088 Series 988 Series Video Peripheral Signal Output DVI RGBHV S Video C Video Model 240 030 930 VISIONELECT VISIONELECT Hospital grade power cord Power Supply 240 030 931 Ground to Cart Chassis Heat shrink tubing between the DC power cord and extension cord 240 030 722 or 240 030 932 VISIONELECT model 240 030 930 ...

Page 12: ...ch Turns the power ON or OFF 3 Rotary Control Turn Right With the on screen display menu activated increases the value of the selected parameter With the on screen display deactivated activates the video source selection menu 4 Rotary Control Turn Left With the on screen display menu activated decreases the value of the selected parameter With the on screen display deactivated activates the video ...

Page 13: ...screen from the second or third level OSD menu select the Exit option To completely exit the OSD press and hold the rotary control If no keys are pressed for a time period the OSD automatically times out 6 While the OSD menu is deactivated rotate the Rotary Control to activate the input signal selection menu The current input signal will be highlighted with a dot Rotate the rotary control to selec...

Page 14: ... Sharpness Set image sharpness from 1 to 10 1 10 Video Sharpness Increase or decrease the video sharpness 0 100 Image Effect Scale Mode Choose scale mode between fill screen V fill H fill or one to one Mirror Enable or Disable mirror image Freeze Frame Enable or Disable freeze frame Zoom Pan Enable zoom in and pan function PIP Enable PIP Picture in Picture function Advanced OSD position Control Co...

Page 15: ...1 Clean the panel with a dry soft cloth or a soft cloth lightly moistened with mild detergent solution Do not use any type of solvent such as alcohol or benzine which might damage the finish 2 Apply alcohol to glass surfaces with soft cotton applicator to aid in cleaning and drying without leaving spots or streaks 3 Dry thoroughly with soft towel or gauze surgical sponge Acceptable cleaning agents...

Page 16: ...C power cord is properly connected to the AC adapter LED Blinking Check if the video signal cable is properly connected at the back of the monitor Check if the power to the computer system is ON Abnormal Picture Oversized or undersized display missing display center shift Using the Auto Setup button adjust CLOCK CLOCK PHASE H POSITION and V POSITION with non standard signals Wait for a few seconds...

Page 17: ...ideo Analog RGB DVI Maximum Pixel Clock 135 MHz 1 Electrical Power Adapter AC 100 240V DC 24V Power Consumption 90W max Current Direct Dimensions Dimensions W H D 499 66 x 428 88 x 104 25mm Weight 17 lbs VESA Mounting Interface VESA 100mm 100mm Operating Conditions Operating Temperature 41 to 90 F 5 to 32 2 C Relative Humidity 10 to 60 Electrical Input Rating 24V DC 3 75A Transport Storage Conditi...

Page 18: ... AIR or WITH OXYGEN OR NITROUS OXIDE This monitor is intended for use on Health Care Facilities model 240 030 930 No user serviceable parts inside Ask qualified personnel before accessing internal components Caution For disposal of waste product follow the requirement of the local code This product is considered electronic equipment It must not be disposed of as unsorted municipal waste and must b...

Page 19: ... equipment even if such equipment meets the applicable emissions requirements Warning Do not use cables or accessories other than those provided with the VISIONELECT model 240 030 930 monitor as this may result in increased electromagnetic emissions or decreased immunity to such emissions Warning If the VISIONELECT model 240 030 930 monitor is used adjacent to or stacked with other equipment obser...

Page 20: ...dance RF emissions CISPR11 Group 1 The VISIONELECT model 240 030 930 monitor must emit electromagnetic energy in order to perform its intended function Nearby electronic equipment may be affected RF emissions CISPR11 Class B VISIONELECT model 240 030 930 monitor is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power ...

Page 21: ...00 4 5 1kV differential mode 2kV common mode 0 5 1kV differential mode 0 5 1 2kV common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC61000 4 11 5 Ut 95 dip in Ut for 0 5 cycle 40 Ut 60 dip in Ut for 5 cycles 70 Ut 30 dip in Ut for 25 cycles 5 Ut 95 dip in Ut for 5 sec 5...

Page 22: ...1000 4 6 3 Vrms 150 kHz to 80 MHz 3 V Recommended Separation Distance Radiated RF IEC 61000 4 3 3 V m 80MHz to 2 5 GHz 3 V m 80 MHz to 800 MHz 800 MHz to 2 5 GHz where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an ele...

Page 23: ...n in which theVISIONELECT model 240 030 930 monitor system is used exceeds the applicable RF compliance level above the VISIONELECT model 240 030 930 monitor system should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the VISIONELECT monitor VISIONELECT model 240 030 930 monitor unit b Over the freq...

Page 24: ...uipment Rated maximum output power W of transmitter Separation distance m according to frequency of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 12 0 23 0 1 0 37 0 37 0 74 1 1 17 1 17 2 33 10 3 70 3 70 7 37 100 11 70 11 70 23 30 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated usin...

Page 25: ...Court San Jose CA 95138 USA Stryker Endoscopy cannot accept responsibility for returns or replacements which have not been authorized This warranty does not cover damages caused by misuse or by failure to follow the procedures outlined in this manual or demonstrated by Stryker Endoscopy representatives There are no other expressed warranties Service and Claims Do not attempt to service this produc...

Page 26: ... requirements of EC Directive 93 42 EEC This declaration is based on compliance testing to EN 60601 1 08 90 EN 60601 1 A1 05 93 EN 60601 1 A2 06 95 This document is on file The CE mark will be affixed based on directive 93 42 EEC Stryker European Representative Regulatory Manager Stryker France ZAC Satolas Green Pusignan Av de Satolas Green 69881 MEYZIEU Cedex France Stryker and Stryker Endoscopy ...

Page 27: ...24 ...

Page 28: ......

Page 29: ...A Stryker Endoscopy 5900 Optical Court San Jose CA 95138 USA 1 408 754 2000 1 800 624 4422 www stryker com European Representative Regulatory Manager Stryker France ZAC Satolas Green Pusignan Av De Satolas Green 69881 MEYZIEU Cedex France ...

Reviews: