Reprocessed by 

 
 

 

 
 

Instructions for Use 
Reprocessed Posey

®

 Chair Alarm Sensor Pad 

 

 

 

Reprocessed Device for Single Patient Use 

 
 

Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician. 

 
 

 

NON-STERILE 

 

Exposed to Ethylene Oxide (EO) gas 

 

 

Explanation of Symbols 

 

Date of Reprocessing 

 

Do Not Reuse 

 

See Instructions For Use 

 

 
Stryker Sustainability Solutions, Inc. © 

2019

 

1810 W Drake Dr.  
Tempe AZ, 85283 

sustainability.stryker.com 
888.888.3433 

 

 

Summary of Contents for Reprocessed Posey

Page 1: ...e Caution Federal U S A law restricts this device to sale by or on the order of a physician NON STERILE Exposed to Ethylene Oxide EO gas Explanation of Symbols Date of Reprocessing Do Not Reuse See Instructions For Use Stryker Sustainability Solutions Inc 2019 1810 W Drake Dr Tempe AZ 85283 sustainability stryker com 888 888 3433 ...

Page 2: ...d DO NOT use any alarm or sensor pad that does not alarm each time it is tested USE OF RESTRAINTS The position of the sensor pad is vital when using a restraint Make sure the restraint is applied correctly per instructions for that device Straps must NOT cross over sensor pad o If straps cross over sensor pad and patient moves pressure from straps may prevent alarm from activating If patient falls...

Page 3: ... activate This is called a failsafe mode Disconnect the sensor pad to make sure the failsafe mode works DO NOT use the alarm if the alarm does not sound when the sensor pad is disconnected 4 When connecting the alarm to the nurse call system check that the nurse call cable is securely connected to the alarm and the nurse call panel ALWAYS test alarm and nurse call function if nurse call cable is p...

Page 4: ...ser of products directly from Stryker or a Stryker authorized distributor This warranty may not be transferred or assigned without the express written consent of Stryker This warranty does not apply to 1 products that have been misused neglected modified altered adjusted tampered with improperly installed or refurbished 2 products that have been repaired by any person other than Stryker personnel ...

Page 5: ...vice This product and its packaging have been exposed to ethylene oxide gas EtO Even though the product then is processed in compliance with all applicable laws and regulations relating to EtO exposure Proposition 65 a State of California voter initiative requires the following notice Warning This product and its packaging have been exposed to ethylene oxide The packaging may expose you to ethylen...