![Stryker PneumoSure Instructions For Use Manual Download Page 60](http://html.mh-extra.com/html/stryker/pneumosure/pneumosure_instructions-for-use-manual_1385986060.webp)
54
Using and Controlling the PNEUMO SURE XL High Flow Insufflator in Vessel Harvest Operating Mode
EN
Briefly press the nominal gas flow function field
»
to reduce the nominal gas
flow.
Safety limit:
The safety limit can be activated or deactivated in the Configuration menu.
When increasing the nominal flow, the status line of the display depicts
Safety
limit
starting at
6 l/min
and the nominal value flashes.
Release the function field to increase the nominal gas flow further. The display
switches back to the nominal value setting after 2 seconds. Now you can set a
value of up to 10 l/min.
CAUTION!
Exceeding this safety limit is to be decided by and the responsibility of the user/
operator.
9.5
Performing the Function Test in Vessel Harvest Operating Mode
before Using the Device during Surgery
Preparation
Sterilize reusable instruments and tubing before surgery to prevent infections.
Check all the single-use/disposable items before removing them from the pack-
age to ensure that the packaging is intact and that the expiration date is still val-
id.
For your own safety and that of your patient, use only original accessories.
WARNING!
The function test must be performed prior to each surgical procedure.
Testing the device
1. The device is switched off, no tube set is connected.
2. Make sure the gas supply is connected and open.
3. Use the ON/OFF switch
(1)
to turn the device on. The device conducts a de-
Fig. 9-1
Layout for testing the device
(1)
ON/OFF switch
(2)
Nominal pressure display
(3)
START/STOP function field
(4)
Gas consumption display
(5)
Nominal flow display
(6)
Insufflation tube set
(7)
Luer Lock connection
(1) (2) (3)
(4)
(5)
(6)
(7)
Summary of Contents for PneumoSure
Page 6: ......
Page 101: ...Appendix 95 EN 19 Appendix 19 1 Test Log Date Results Comment Signature ...
Page 104: ......
Page 107: ...3 ES 19 Apéndice 100 19 1 Registro de test 100 Índice alfabético 101 ...
Page 108: ......
Page 204: ...100 Apéndice ES 19 Apéndice 19 1 Registro de test Fecha Resultado Anotaciones Firma ...
Page 209: ...3 FR 19 Annexe 99 19 1 Procès verbal de tests 99 Index alphabétique 100 ...
Page 210: ......
Page 305: ...Annexe 99 FR 19 Annexe 19 1 Procès verbal de tests Date Résultat Remarque Signature ...
Page 308: ......
Page 405: ...Anexo 97 PT 19 Anexo 19 1 Protocolo de teste Data Resultado Anotações Assinatura ...
Page 408: ......
Page 409: ......