Page 1: ...N Nä är ra a H Ho os sp piit ta all B Ba as ss siin ne et t O Op pe er ra at tiio on ns s M Ma an nu ua all 4402 EN 4402 009 001 Rev E 0 2019 08 ...

Page 2: ......

Page 3: ...sult instructions for use General warning Caution Catalogue number Serial number Quantity UNIT Unit number For US Patents see www stryker com patents Manufacturer Safe working load Do not place infant newborn on this surface 4402 009 001 Rev E 0 EN ...

Page 4: ......

Page 5: ...sket to the base cabinet 9 Removing the basket from the base cabinet 10 Accessing the infant newborn from the basket 10 Tilting the basket 11 Raising and lowering the bassinet 11 Opening and closing the retractable work surface 12 Opening and closing the two way drawers 12 Storing records in the chart holder 13 Applying and releasing the caster locks 14 Applying and releasing the steer caster 14 T...

Page 6: ... the basket before removing the basket from the base cabinet to avoid the risk of patient fall Do not raise the hospital bed when the bassinet is near to avoid interference that may cause instability or tipping Do not place items above or below the functional areas of the bassinet Do not push the product from the sides to avoid instability Do not lift the bassinet by the basket or by the adjustmen...

Page 7: ...e sure that you wipe each product with clean water and thoroughly dry each product after cleaning Some cleaning products are corrosive in nature and may cause damage to the product if you use them improperly If you do not rinse and dry the product you may leave a corrosive residue on the surface of the product Failure to follow these cleaning instructions may void your warranty Do not over expose ...

Page 8: ...The Stryker model 4402 N Nä är ra a Hospital Bassinet consists of a base cabinet two way drawers retractable work surface five inch soft wheel casters a clear basket and mattress The basket allows for easy access to the infant newborn patient tilts and latches securely onto the base cabinet I In nt te en nd de ed d u us se e The N Nä är ra a Hospital Bassinet is a sleeping surface for infant newbo...

Page 9: ...n 25 4 cm n a Chart holder 10 in 25 4 cm 2 75 in 6 9 cm 13 5 in 34 2 cm Mattress 26 in 66 04 cm 12 in 30 48 cm 1 5 in 3 81 cm Mattress material Polyester fiber 100 all new material Adjustable height 30 5 in to 39 5 in 77 4 to 100 cm E En nv viir ro on nm me en nt ta all c co on nd diit tiio on ns s O Op pe er ra at tiio on n S St to or ra ag ge e a an nd d t tr ra an ns sp po or rt ta at tiio on n...

Page 10: ... L 5 dual soft wheel casters C Co on nt ta ac ct t iin nf fo or rm ma at tiio on n Contact Stryker Customer Service or Technical Support at 1 800 327 0770 Stryker Medical 3800 E Centre Avenue Portage MI 49002 USA To view your operations or maintenance manual online see https techweb stryker com Have the serial number A of your Stryker product available when calling Stryker Customer Service or Tech...

Page 11: ...older Figure 1 A F Fiig gu ur re e 1 1 S Se er riia all n nu um mb be er r llo oc ca at tiio on n U Un niit t n nu um mb be er r Have the unit number of your basket A or mattress B available when calling Stryker Customer Service or Technical Support Include the unit number in all written communication A B 4402 009 001 Rev E 0 7 EN ...

Page 12: ...r digits of the serial number S Se et tu up p During setup unpack the cartons and check all items for proper operation Make sure that the product is working properly before it is put into service Remove all shipping and packaging materials from the product prior to use EN 8 4402 009 001 Rev E 0 ...

Page 13: ... work surface or chart holder C CA AU UT TI IO ON N Do not remove or install the basket while occupied Do not place an infant newborn in the drawers on the retractable work surface or on the base cabinet Do not place items between the basket and the base cabinet Do not carry the basket with the tilt bar Do not use this product to perform medical procedures N No ot te e The bassinet is not for use ...

Page 14: ...of patient fall C CA AU UT TI IO ON N Do not place an infant newborn in the drawers on the retractable work surface or on the base cabinet To remove the basket from the base cabinet 1 Remove the infant newborn from the basket 2 Remove the mattress from the basket 3 Reach through the cut out window on the basket then grasp and lift the tilt bar 4 Tilt the basket upward and slide basket off the two ...

Page 15: ...3 Lift the basket slightly and lift the tilt bar from the slot Figure 6 4 Lower the basket R Ra aiis siin ng g a an nd d llo ow we er riin ng g t th he e b ba as ss siin ne et t W WA AR RN NI IN NG G To avoid tipping hazards of this device make sure that the basket and accessories sit firmly in the base and that all doors drawers and casters are secure Do not raise the hospital bed when the bassin...

Page 16: ...rking load of the drawers basket retractable work surface or chart holder C CA AU UT TI IO ON N Do not place an infant newborn in the drawers on the retractable work surface or on the base cabinet To open or close the retractable work surface 1 To open the retractable work surface pull outward F Fiig gu ur re e 9 9 O Op pe en n o or r c cllo os se e t th he e r re et tr ra ac ct ta ab blle e w wo ...

Page 17: ...y y d dr ra aw we er rs s 2 To close the two way drawers push the drawer inward N No ot te e There is a magnetic detent in the middle of the drawer that helps to center the drawer when closed Do not overfill the drawers it may prevent closure 3 Make sure the drawers are closed before moving the device S St to or riin ng g r re ec co or rd ds s iin n t th he e c ch ha ar rt t h ho olld de er r W WA...

Page 18: ...h your foot F Fiig gu ur re e 1 13 3 A Ap pp plly y t th he e c ca as st te er rs s f fo or r s st te ee er riin ng g 2 To release the steer caster lift up on the green caster pedal with your foot T Tr ra an ns sp po or rt tiin ng g t th he e b ba as ss siin ne et t W WA AR RN NI IN NG G To avoid tipping hazards of this device make sure that the basket and accessories sit firmly in the base and th...

Page 19: ...y the steer caster if applicable 4 Grasp the transport handle and push the bassinet forward A Ap pp plly yiin ng g t th he e n na am me e c ca ar rd d o op pt tiio on na all C CA AU UT TI IO ON N Always apply the name card to the outside of the basket to avoid the risk of choking 1 Write on the name card with permanent marker 2 Peel the name card and apply to the outside of the basket F Fiig gu ur...

Page 20: ...ay be available for use with your product Confirm availability for your configuration or region Call Stryker Customer Service 1 800 327 0770 N Na am me e P Pa ar rt t n nu um mb be er r Basket 4402 010 011 Mattress 4402 031 003 EN 16 4402 009 001 Rev E 0 ...

Page 21: ...um chloride 0 154 Isopropanol 21 000 Non active ingredient Ethylene Glycol Monobutyl Ether 3 N No ot te e For safety information read the product label To clean or disinfect the external product surface 1 To clean wipe external surfaces with a fresh clean wipe to remove all visible soils Repeat as necessary until the product is clean N No ot te e Use as many wipes as necessary Complete step 1 befo...

Page 22: ...ach product with clean water and thoroughly dry each product after cleaning Some cleaning products are corrosive in nature and may cause damage to the product if you use them improperly If you do not rinse and dry the product you may leave a corrosive residue on the surface of the product Failure to follow these cleaning instructions may void your warranty T To oo olls s R Re eq qu uiir re ed d Mi...

Page 23: ...h product after cleaning Some cleaning agents are corrosive in nature and may cause damage to the product if you use them improperly If you do not properly rinse and dry the product a corrosive residue may be left on the surface of the product that could cause premature degradation of critical components Failure to follow these cleaning instructions may void your warranty Recommended disinfectants...

Page 24: ...lowing items All fasteners are secure Chart holder for damage All four casters swivel properly All four casters are free of wax and debris All mechanisms operate freely Two basket retention pins and tilt bar retainer are intact and secure Retractable work surface is intact and secure Basket tilt bar is intact Drawers are intact and slide Push handles Height adjustment bars Bassinet raises and lowe...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...Stryker Medical 3800 E Centre Avenue Portage MI 49002 USA 4402 009 001 Rev E 0 WCR AB 4 2019 08 ...