background image

PN 54171

 

33” DEEP SELF

-

SERVICE REFRIGERATED BAKERY MERCHANDISER

 

READ AND SAVE THESE INSTRUCTIONS

 

Rev S Date: 9.30.2019

 

I:\Oper Manuals 

-

 PUB\Harmony\HMOXX53R_5194_5194R_5163_5749_54171.pub

 

INSTALLATION AND

 

OPERATING MANUAL

 

>>> Model HMO2653R (26 7/8”L* x 34 3/4”D x 52 3/4”H**)             

 

>>> Model HMO2653R.5194 (26 7/8”L* x 34 3/4”D x 52 3/4”H**)

 

>>> Model HMO3953R (38 7/8”L* x 32 1/8”D x 52 3/4”H**)             

 

>>> Model HMO3953R.5749 (38 7/8”L* x 32 1/8”D x 58 3/8”H**)             

 

>>> Model HMO5153R (50 7/8”L* x 32 1/8”D x 52 3/4”H**)

 

>>> Model HMO5153R.5163 (50 7/8”L* x 32 1/8”D x 41 3/4”H**)    

 

>>> Model HMO6353R (62 11/16”L* x 32 1/8”D x 52 5/8”H**)

 

>>> Model HMO7553R (75 1/4”L* x 32 1/8”D x 52 5/8”H**) 

 

>>> Model HMO9653R.5914E (99 1/2”L* x 34 1/8”D x 52 5/8”H**) 

 

 

 

  *Includes 1” End Panels   

 

**Includes Levelers at 1 1/4” Below Base Frame

 

888 E. Porter Road ∙ Muskegon, MI  49441  Phone: 231.798.8888  Fax: 231.798.4960  www.structuralconcepts.com

 

HMO2653R

 

HMO5153R

 

HMO2653R.5194

 

HMO5153R.5163

 

(Shown With Risers)

 

HMO7553R

 

HMO3953R.5749

 

HMO9653R.5914E

 

(Shown With Optional Recipe 

Card Holders)

 

Summary of Contents for HARMONY HMO2653R

Page 1: ...38 7 8 L x 32 1 8 D x 58 3 8 H Model HMO5153R 50 7 8 L x 32 1 8 D x 52 3 4 H Model HMO5153R 5163 50 7 8 L x 32 1 8 D x 41 3 4 H Model HMO6353R 62 11 16 L x 32 1 8 D x 52 5 8 H Model HMO7553R 75 1 4 L...

Page 2: ...AIR CURTAIN OPTIONAL OPERATING INSTRUCTIONS MAINTENANCE FUNDAMENTALS SHELF ASSEMBLY REMOVAL FLUORESCENT LIGHTS MAINTENANCE FUNDAMENTALS CONTINUED LED LIGHT FIXTURES MAINTENANCE REFRIGERATION PACKAGE I...

Page 3: ...nstallation site may result in SEVERE DAMAGE to unit when transporting to final destination Structural Concepts strongly recommends that equipment ONLY be uncrated at installation site 4 Damage Discov...

Page 4: ...state and local electrical and plumbing codes are not covered by warranty See below compliance guideline WARNINGS This page contains important warnings to prevent injury or death Please read carefull...

Page 5: ...d carefully See previous page for specifics on OVERVIEW CONDITION TYPE COMPLIANCE and WARNINGS WIRING DIAGRAM Each case has its own wiring diagram folded and in its own packet Wiring diagram placement...

Page 6: ...ty may cause case to fall C Unlock Casters Slide unit to rear of skid Slide down ramp and off from skid Note Illustrations reflect general outline of sample case and may not reflect your particular mo...

Page 7: ...s Sanitation and Refrigeration See illustration at below right for outline of caulk sealant lines D Line up second case bolt hole to bolt hole to first case E Using SCC supplied bolts found in install...

Page 8: ...adjoinment of model HMO3953R 5749 with separate model DP812R 5748 Model DP812R 5748 has its own operating manual SCC P N 20 32217 End Cap Model HMO3953R 5749 See SCC P N 54171 For Operating Manual Mo...

Page 9: ...6 Position Align Case Alongside Other Cases Before adjusting levelers or shimming frame support rails make certain that the case is in proper position and if required aligned with adjoining case s Th...

Page 10: ...5749 condensate package Case wiring source is from its adjoining case SCC P N DP812R 5748 Note Depending upon features and options chosen illustration below may not reflect every aspect of your parti...

Page 11: ...ntained Units Controller Ballast box location is at customer rear See illustration at left Below illustrations show layout of controller ballasts main power switch door lock terminal block etc after r...

Page 12: ...rain 10 Electrical Connections Certain Remote Cases Field wiring connection electrical access location is at customer left side of case Single phase leads are provided 11 Evaporator Fan Area Illustrat...

Page 13: ...of Evaporator the Hose and Drain Trap MUST BE secured and positioned over Evaporator Pan to prevent water seepage spillage When sliding out Condenser Unit be careful that drain is not pulled from prop...

Page 14: ...s in proper position adjust case so it is level and plumb see illustrations at right You may need to remove front and or rear Toe Kick to access levelers Use adjustable wrench to adjust leveler Depend...

Page 15: ...orward and can be lifted up and away from case Replace Front Grille in reverse order it was removed from case Tighten retainer screws Grille Removal Without Screws Front grille is held in place with r...

Page 16: ...is held in place with four Phillips not flat head screws which may be removed 4 Compressor Pan Shipment Screws Note At initial access to refrigeration package it may be necessary to remove compressor...

Page 17: ...the lights Whether Remote or Self Contained light switch is located on inside of case at top right from case rear See illustration at top right All lights should come on at same time First time lighti...

Page 18: ...the handle at lower front center area of case shown in enlarged view at lower left and pull upward 5 When extended the Night Air Curtain magnets may be attached to metal plate in front of honeycomb as...

Page 19: ...r a specific model Your model may not reflect this feature See next page for case with rear door with Rear Hinged Door With Handle access to perforated Plexiglas plenum designed to assist in air flow...

Page 20: ...he Plexiglas plenum may be removed for cleaning etc by opening the rear door and sliding up and out of frame Perforated Plexi Plenum Caution See cleaning instructions in this manual for specifics on c...

Page 21: ...num for cleaning etc Caution See cleaning instructions in this manual for specifics on cleaning the plexiglas ple num Using cleaning solutions that are not listed in this manual can mar plexiglas surf...

Page 22: ...After securely positioned in the Baffle Airflow Slots carefully and slowly lean the Security Grid back against the two Security Brackets 4 The next page in this manual will show how to secure the top...

Page 23: ...Into Place and Locking 1 After leaning the Security Grid back against the two Security Brackets slide the two Padlocks through the Security Grid and the Security Brackets 2 Securely lock the Padlocks...

Page 24: ...om its magnetic attachment and carefully wind Night Air Curtain back into roll 5 Caution Do not allow spring loaded Night Air Curtain to freely snap back into roll Doing so can eventually destroy Nigh...

Page 25: ...and pulling the remaining contact from the sockets Installation of lamp Align pins with slot Insert pins into socket by rotating the bulb 1 4 turn to secure either the upper or lower pinned contacts i...

Page 26: ...lustrations at right 4 Plug And Cord Positioning Plug is to connect to LED light at raceway side of case Before attaching LED light to case verify that plug connects to LED properly without cord doubl...

Page 27: ...y have different refrigeration package layout Wicking material shown below is optional See DRAIN HOSE AND BRACKET PLACEMENT ILLUSTRATIONS section in this manual for other refrigeration layouts Compres...

Page 28: ...er has dried return to case See REFRIGERATION FUNDAMENTALS section in this manual for il lustrations Case Interior Daily Shelves Decks Risers Shelves decks and risers can be cleaned with a warm soap a...

Page 29: ...e wiping with clean sponge after EACH cleaning Dry with clean soft cloth or paper towel Removing Streaks or Stains Method 1 Place two teaspoons of rubbing alcohol on a microfiber cloth or pad Rub the...

Page 30: ...e on call service provider Case is Not Holding Proper Temperature If a large amount of warm product was added to the case it will take time for the temperature to adjust Product must be pre chilled be...

Page 31: ...n off case and disconnect plug from wall outlet before beginning tub drain cleaning Vacuum tub under decks Clean with soap and water solution Wipe dry with clean cloth Keep drain free of debris to pre...

Page 32: ...r connected Caution Evaporator pan may be malfunctioning Electrical Heat Rod Evapora tor system If so water will overflow pan and seep onto flooring causing damage Until evaporator pan is functioning...

Page 33: ...eck that the MAIN power switch is on Check that fans are plugged in at the fan shroud Check for foreign material obstructing fan performance Check that fan blades freely rotate within fan shrouds Chec...

Page 34: ...or air conditioning vent See OVERVIEW AND WARNINGS section in manual for adverse conditions spacing issue parameters If case is located near front doors temperature fluctuation can hinder unit s abil...

Page 35: ...on condensable is not in the system Check that Liquid Line Drier is not plugged Check that there are no close offs around Condensing Coil Check Set Point Temp it may be adjusted too high Check System...

Page 36: ...t High Superheat doesn t need adjusting Check that the Thermostatic Element charge isn t depleted Check that there is air no seepage of air around Condensing Coil Check that the Coil is not iced up Hi...

Page 37: ...scrubbing method Electric heater coil evaporator pans can be removed and cleaned After thoroughly cleaning pan with scrub brush and solution rinse thoroughly with clean water in spray bottle and wipe...

Page 38: ...omb to allow it to be pulled out of honeycomb retainer C Carefully pry downward and away from the honeycomb retainer Clean honeycomb with warm water and soap A B C D E F solution Submerse if necessary...

Page 39: ...el For Refrigerated Case Sample Serial Label For Non Refrigerated Case 39 SERIAL LABEL LOCATION INFORMATION LISTED TECH INFO SERVICE Serial Label Location Information Listed Technical Information Serv...

Page 40: ...timeout occur normal operational settings prior to modifications being made will resume 3 If the instrument is switched off before pressing the Prg key all modifications to parameters will be lost Se...

Page 41: ...set reset HACCP alarms reset temp monitoring Summary Table of Alarm and Signals Display Buzzer and Relay Integrated Electronic Microprocessor Controller Read And Save These Instructions Page 2 of 3 Us...

Page 42: ...F 50 200 dP1 Maximum defrost duration evaporator min F 1 250 d6 Display on hold during defrost C 0 2 dd Dripping time after defrost min F 0 15 d 1 Display of defrost probe 1 C F F 42 For Case Specifi...

Page 43: ...onable attorney fees and costs Remedies of SCC SCC s rights and remedies shall be cumulative and may be exercised from time to time In a proceeding or action relating to the breach of this Agreement b...

Reviews: