Adjusting the
distance
1. Adjust the distance between the spark-type brush
holder (114) and the slip ring (11) to mounting di-
mension n=3 mm.
2. Connect the spark-type brush holder to the electrici-
ty. Use the enclosed soldering cable shoe form A as
per DIN 46211 for this purpose, see section 2.5, by
clipping the customer's connection cable into it.
CAUTION
Risk of accidents due to electric shock
Operation without the use of the supplied rubber cap
can result in contact with live components or damage.
► Operation is only permitted with fitted rubber cap.
3. Fit the rubber cap (115).
SKB-0114_02
11
115
114
n
Fig. 21
6.6
Check the air gap
Use a suitable
measuring tool
1. Use a suitable measuring tool (e.g. feeler gauge,
see Stromag - Accessories) for the width of the air
gap ((La) when engaged between the coil body (2)
and armature plate (4)), see section 4.4.
La
SKB-0124_05
5
2
4
Fig. 22
33
Mounting instructions Electromagnetic multi-disc clutch EKE/EKB, EDE/EDB • No. 500-00000 C • 10/2017