background image

 

 

MANUAL FOR STROCO 

PURE 

ELECTRIC HEATER  

60 kW 

STROCO ApS, Energivej 3, DK-6800 Varde, tel. +45 86961066 

 
 
GB 05/21 

This manual is also available at www.stroco.dk

 

Summary of Contents for 672V DC

Page 1: ...MANUAL FOR STROCO PURE ELECTRIC HEATER 60 kW STROCO ApS Energivej 3 DK 6800 Varde tel 45 86961066 GB 05 21 This manual is also available at www stroco dk ...

Page 2: ...e following must at least be met 1 Installation is performed as described in this manual 2 Service and repair work must be carried out professionally correctly 3 Only original spare parts shall be used 4 The heater may only be used for the voltage shown on the type plate ...

Page 3: ...CONTENTS PAGE 3 Page Description 4 Built in dimentions 5 Marking STROCO Electric heater 6 Electrical installation and settings 7 Coupling scheme 8 9 Warranty conditions 10 Dealers 11 ...

Page 4: ...ts The HVDC contactor is controlled via the electrical mechanical contactor inside the connection box which re ceives an active 24VDC signal from the vehicle s heat control system to pull the HVDC contactor When the temperature is reached the mechanical contactor breaks the 24 voltage to the HVDC con tactor For circulation of the water the 24V DC water pump is located on the heater and needs a 10 ...

Page 5: ...ion Part number 1 Heating element 15 kW 672V DC 11 936 1 2 VP 6000 L h 24V DC 7A 0 4 bar 35 470 3 Multi 2pole pin plug sleeves 6 3mm 13 561 4 Thermostat EGO 37 85 C 110 11 926 5 Terminal Block 11 915 6 Boiler Std Grey 35 544 6 Boiler Color RAL 5015 Blue 35 544 10 ...

Page 6: ...MARKING STROCO ELECTRIC HEATER PAGE 6 Label on connection box ...

Page 7: ...oth disc may be used 2 Thermostat Operating thermostat can be set steplessly from 37 C to 85 C The thermostat has a built in hystere sis of 12 K i e there is 12 C between the connecting and dissconneting The operating temperature is set with a screwdriver at The safety thermostat disconnects if the temperature exceeds 110 C The thermostat can be reconnected by pressing the red button Note The sett...

Page 8: ...COUPLING SCHEME FOR 4 X 15 kW 672V DC PAGE 8 15 kW ...

Page 9: ...COUPLING SCHEME FOR 4 X 15 kW 672V DC PAGE 9 15 kW ...

Page 10: ...or parts are not covered by STROCO If you observe defects in the system during the warranty period the defective parts should be sent postage paid to STROCO with information about the defect and delivery date heater no STROCO s assessment of the defect and whether it is covered by the warranty will always be final and binding for the customer STROCO will only accept warranty claims that have been ...

Page 11: ...CARE ON SEA Spf Tel 298 74 88 55 Úti vio Neyst 11 E mail FO 430 Hvalvik careonsea gmail com NORGE Norway VEST SERVICE AS Tel 47 90 85 60 00 Visnesvegen 9A E mail N 6783 Stryn post vest no POLEN Poland MULTITECH sp z o o Tel 48 12 638 06 63 Spcerowa 49 E mail PL 32 070 Dabrowa Szlachecka biuro multitech krakow pl PORTUGAL PROJECTIVA Tel 351 249 819 240 Zona Industrial E mail Apartado 175 geral proj...