background image

 

REV 2.1 

Generation 4

Instruction manual

Summary of Contents for G4 1000 Gold

Page 1: ...REV 2 1 Generation 4 Instruction manual ...

Page 2: ...tely rust free units are constructed from high grade aluminium and stainless steel Elements are quick and easy to replace Manufactured in South Africa Parts available locally Dimmable to control heat and save electricity dimmer sold separately Generation 4 Models The table below lists the heaters that is available in our Generation 4 range Short Wave Quartz Halogen Elements Power Ultimate Amber Ra...

Page 3: ...llow any heat build up Do not install on any plastic or surface other than cement steel or concrete Ensure proper insulation when installing on a wooden surface The minimum ventilation openings around the heater after installation must be between 100 and 200 mm from the top and sides and at least 1500 mm away from any combustible materials or flammable items chemicals furniture carpets clothes cur...

Page 4: ...ch the Quartz Halogen elements If you do need to clean the element before switching the heater on for the first time please refer to the paragraph titled Cleaning the heater on page 8 and follow the instructions carefully Included in the box Your new Striking Energy Generation 4 infrared heater two 4 mm hex screws already located in the bracket slot on the heater Sealed packet with the following i...

Page 5: ...ater It is based on an average level of optimal comfort for each heater and is generally the optimal heigh you could choose Shade Think of infrared heat as being similar to light rays which means it can cast shadows Imagine your heater is a light The shaded areas will not receive direct heat although it receives a lower level of scattered light The more heaters you install in an area the higher th...

Page 6: ...must ensure that they have sufficient amperes available for larger installations To be legally complaint all installations must be done by an electrician Location Always keep the area that you are living in as well as the positioning of the installation e g south in mind You will have to compensate for this when choosing the optimal place and angle of installation You can either install more heate...

Page 7: ...ng the position where you want to install the heater These holes must be between 100 and 300mm apart and LEVEL 3 Drill a 6 mm hole about 70 mm deep on both positions 4 Fix Both Wall brackets using the supplied 6 mm anchor screws plastic inserts 5 Fix the heater to the wall brackets using the supplied M4 hex bolt 6 Connect the electrical wire to the supply as per building regulations Page of www st...

Page 8: ... sufficient time to cool down before cleaning Do not handle the element with bare hands If it is inadvertently touched remove any and all finger marks with a soft cloth or paper towel and methylated spirit or alcohol Otherwise the marks will burn into the element causing premature heater failure Do not touch the element with any object including cigarettes Cleaning the heater Your heater should be...

Page 9: ...Gen 4 Parts diagram and exploded view Quartz Halogen models G4 Models 2019 and later Page of www striking co za info striking co za 9 15 ...

Page 10: ...ow the steps applicable to your heater type Replacing the Quartz Halogen element Note Throughout the entire process never touch the glass part of the new Quartz Halogen element You can easily replace the element by carefully holding the ceramic caps at the ends of the element These instructions apply to both single and double body heaters Please note special instructions for your type of heater wh...

Page 11: ...e element from the front of the heater Feed one of the cables through the opening and follow with the ceramic cap Carefully push the element through so that the other side can be inserted 2 Lower the element into the smaller parts of the openings 3 Replace the small reflective inserts carefully Bend them back towards each other but only about of the way in order to allow for easy removal in the fu...

Page 12: ...Gen 4 dimensions Page of www striking co za info striking co za 12 15 ...

Page 13: ...Steel Electrical requirements 1000 watt 5 Amp 1500 watt 7 Amp 2000 watt 9 Amp All heaters 230 Volt 50 Hz 3000 watt 14 Amp 4000 watt 18 Amp All heaters 230 Volt 50 Hz Overall dimensions 380 x 110 x 105 mm 760 x 110 x 105 mm Preferred burning position Horizontal as well as vertical position Element life Half life of 5000 hrs for Ruby and Gold Electrical cable Three core 1 5 mm silicone Open ended Th...

Page 14: ...t If a warranty replacement part is required customer shall provide Purchase Order to Striking Energy prior to shipment of the replacement to guarantee the return of the rejected unit Purchase Order is valid until suspected part is received and warranty is confirmed by assessment Once a return authorization is obtained the customer is responsible for packing and shipping the product component to w...

Page 15: ... the equipment when used in combination with equipment not purchased specified or approved by Striking Energy 5 Batteries and other consumable goods 6 Wearable items such as elements tooling cables part harnesses contacts etc ADDITIONAL WARRANTY NOTES 1 OEM or third party equipment that is incorporated into Striking Energy equipment is covered under the applicable Striking Energy Standard Equipmen...