1. Check manufacturer’s specification on item to be inflated for correct inflation pressure.
2. Remove valve cap cover from valve stem.
3. Insert proper valve stem adapter into stem connector as far as possible and turn the locking thumb lever to down
position.
4. Insert other end of valve stem adapter into inflatable air valve stem as far as practical.
5. Set the compressor on/off switch to “on” position.
6. Monitor pressure on air pressure gauge. When desired pressure is reached, turn off compressor, turn the locking
thumb lever to up position and remove stem connector from valve stem. Also remove valve stem adapter if
applicable. Replace valve cap on valve stem.
STORAGE:
This unit may be stored in any position. Make sure the clamps are secure inside the booster cable
storage covers. Store at room temperature. If not used for a prolonged period of time, recharge every 2 months in
the winter and every month in the summer.
SPECIFICATIONS
Battery:
12 volt 8AH sealed lead acid, maintenance free, spill-proof, rechargeable.
Power Supply DC Output:
12-volts nominal. Up to 10 Amps with auto reset protector
Power Supply Charging Time:
24 hours with AC charger;
6 hours to recharge with 12-volt DC charger.
Storage Temperature:
Store in a cool dry area.
The WEEE symbol
on this product means that this product should be ethically dismantled or recycled to
minimise environmental impact. Please check with your local authority for more information.
IMPORTANT:
ADDITIONAL SAFETY INFORMATION
This Power Station/Emergency Jumpstart is
NOT
intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are supervised or
have been given instruction concerning use of the Power Station/Emergency Jumpstart by a person responsible
for their safety.
EC DECLARATION OF CONFORMITY
In accordance with EN ISO 170504:2004
We;
The Ace Supply Co Ltd., T/A Streetwize Accessories
Of;
Unit 9, Warth Rd Ind Estate, Warth Road, Bury,Lancashire BL9 9NB
And in accordance with the following Directive(s):
2004/108/EC
The Electromagnetic Compatibility Directive
2006/42/EC
The Machinery Directive
hereby declare that:
SWPP4 - Power Station with Air Compressor
is in conformity with the applicable requirements of the following directives:
EN55014-1:2006, EN55014-2:1997+A1:2001, EN55015:2006+A1:2007, EN61541:1995+A1:2000,
EN61000-3-2:2006, EN61000-3-3:2008, EN61558-1:1997+A1:1998+A11:2003, EN61558-2-4:1997,
EN61558-2:17:1997, EN60950-1:2006, EN60335-1:2002+A1:2004+A2:2006+A11:2004+A12:2006
2011/65/EU Verification Testing Of Restriction Of hazardous Substances (ROHS)
Signed by: Name:
Antony Collier - QC Manager
Signed at Bury on 18/12/12
12v
Portable Power Station & Emergency
Jumpstarter with Air Compressor
SWPP4
• High Impact Resistant Rubberized Housing
• 300 AMP Jump Start System
• Reverse Polarity Indicator
• 260 PSI Air Compressor with Pressure Reading Gauge
• 12 Volt Power Station
WELCOME:
This product has been carefully engineered and manufactured to give you dependable operation.
Please read this manual thoroughly before operating your new product as it contains the information you need to
become familiar with its features and obtain the performance that will bring you continued enjoyment for many
years. Please keep this manual on file for future reference.
IMPORTANT:
PRIOR TO USE, READ AND UNDERSTAND ALL WARNINGS, CAUTIONS AND INSTRUCTIONS INCLUDED
IN THIS INSTRUCTION MANUAL, AND THOSE PUBLISHED BY YOUR VEHICLE BATTERY MANUFACTURER AND
MANUFACTURER OF ANY DEVICE INTENDED TO BE USED WITH THIS UNIT. RETAIN THESE INSTRUCTIONS FOR
FUTURE REFERENCE.
LOCATION OF CONTROLS
1. High Impact Resistant
Rubberized Housing
2. Jump Start System Power Switch
3. Reverse Polarity Indicator
4. Battery Status Check Button
5. Battery Status Indicator
6. Charging Jack
7. 12 Volt Power Outlet
8. 260PSI Pressure Reading Gauge
9. Air Compressor On/Off Switch
10. AC Charger
11. DC Charger
FIRST AID:
Make sure fresh water and soap are available nearby in case battery acid contacts skin, eyes or
clothing. If contact with battery acid occurs, rinse immediately and thoroughly with water. Then wash with soap and
water. Obtain immediate medical attention if redness, irritation or pain is present. For eye contact, flush eyes for at
least 15 minutes and obtain immediate medical attention.
CAUTIONS
• Never work alone with this product. Make sure that someone is available to give assistance if needed.
• Wear complete eye and clothing protection. Do not touch eyes while working near battery.
• Do not attempt to remove or replace the battery used in this device. When the battery has reached the
end of it’s useful lifetime, take the entire unit to a battery recycling facility.
• For proper and safe operation of the 12 Volt DC power accessory outlets, do not place anything into it
except the plug of the accessory to be used.
• Remove metal personal jewelry, such as rings, bracelets, necklaces and watches while working with a
lead-acid battery. It can produce a short-circuit that may cause severe burns.
• Never charge or jump-start a frozen battery.
• Never allow clamps (positive & negative terminals) to touch together or to connect the same piece of
metal to prevent short-circuits and arcing.
• Do not operate this device while wearing vinyl clothing. Static electricity may be generated when vinyl
clothing is rubbed.
• This product is not intended for use in the rain or temperatures above 130˚F.
• Use only the provided chargers, cables and clamps. Unauthorized parts may damage the unit.
• This product is not a toy. Keep out of the reach of children.
• Keep battery terminals clean. Be careful to keep corrosion from coming in contact with eyes.
RoHS
COMPLIANT
Lancashire