Streamline SMARTANK Instruction Manual Download Page 1

These instructions identifies a risk situation  

which could lead to serious injury. MUST  

read before operating the 

SMARTANK®  

tank system. 

SMARTANK 

®

I N S T R U C T I O N   M A N U A L 

SMT400

SMT650

SMT1000

Codes:

Availible Variations:

- 400ltr, 650ltr or 1000ltr tank options

- Water delivery, de-ionising (DI) resin  
  filtration and reverse osmosis with DI       
  (RODI) filtration 

- It is also possible to have the
  SMARTANK® tank system on a skid  
  mount, installed into a trailer system or  
  installed into a vehicle. It is  
  therefore important for the operator  
  to read all instructions provided by  
  the manufacturer.

INSTR-SMT

English

Summary of Contents for SMARTANK

Page 1: ... Codes Availible Variations 400ltr 650ltr or 1000ltr tank options Water delivery de ionising DI resin filtration and reverse osmosis with DI RODI filtration It is also possible to have the SMARTANK tank system on a skid mount installed into a trailer system or installed into a vehicle It is therefore important for the operator to read all instructions provided by the manufacturer INSTR SMT English...

Page 2: ...instructions and regulations The SMARTANK tank system is not intended for use by children adolescents persons under the influence of alcohol drugs or simply lacking experience and knowledge These operating instructions are designed to educate the user informing t he operator how to carry out the task at hand successfully whilst avoiding potential dangers that might occur Please read the warning an...

Page 3: ... Male hose lock 3 4 inch 3 4 inch 3 4 inch Pure Water Outlet Connection Male hose lock 3 4 inch 3 4 inch 3 4 inch Electrical Power Supply 12v Battery 230V mains 12v Battery 230V mains 12v Battery 230V mains Optimum Water Quality 000ppm 000ppm 000ppm Water Quality Range 000ppm 1000ppm 000ppm 1000ppm 000ppm 1000ppm Pure Water Flow optimum output 5 2 Lpm Per Pump 5 2 Lpm Per Pump 5 2 Lpm Per Pump Ope...

Page 4: ... connected via an extension use cables with an adequate cross section never less than 1 5 mmq The plug and socket must be watertight The electrical safety of the equipment is guaranteed only when correctly and efficiently earthed as specified in current electrical safety legislation in compliance with the provisions of the IEC 60364 1 standard This fundamental safety requisite should be verified I...

Page 5: ...tive Footware Protective Gloves The SMARTANK tank system is manufactured with the safety of the operator in mind including some key features such as If the water pressure in the SMARTANK filtration system rises above the maximum 100psi 6bar pressure the pressure switch valve shuts on the pump closing the system down and not letting the pressure in the system rise any further It is important to nev...

Page 6: ...sels Do not allow them to dry out v Ensure you reinstall the prefilters and DI resin cartridge Do not allow them to dry out vi Remove the prefilter housing and pour out the excess water vii Remove the DI resin cartridge housing and pour out the excess water viii Remove the RO membrane caps for the excess water to drain from the membranes ix Remove all filters from the SMARTANK system wrap in indiv...

Page 7: ...rator TDS meter Final deionising operator TDS meter RODI Filtration Cabinet lid DI Filter 1 Reverse Osmosis RO TDS meter Pre filtration filters sediment filter granular activated carbon filter carbon filter Electric Solenoid Valve STREAMLINE digital flow controller 1 STREAMLINE digital flow controller 1 Booster Pump Pressure Waste Water Regulator Final deionising operator TDS meter Filling electri...

Page 8: ... your vehicle battery and taking charge from the vehicle when on and in motion The split charge relay should already be installed in your vehicle system however if need assistance please speak to the manufacturer or a STREAMLINE fitting centre To operate the SMARTANK system the operator needs to think of a suitable filling time before commencing on the cleaning task Filling time takes approx 2 4hr...

Page 9: ...E charger supplied with your SMARTANK system If misplaced contact your dealer of manufacture immediately The charger will never over heat This has a safety function to prevent the battery from over charging You can operate the system and keep the battery on charge Pay special attention to the mains electrical supply when operating with water i Plug charger into an electrical socket ii Insert the c...

Page 10: ...ortant Your SMARTANK does not have any filtration therefore the operator MUST fill the tank with pure 000ppm water i Connect the BLACK hose from the mains water supply to the water inlet connection do not turn water supply on yet iii Ensure that the waste water regulator valve for the Reverse Osmosis filter is fully open turn anti clockwise iv Switch the solenoid valve on with the solenoid switch t...

Page 11: ... and shut the water off at the ports Disconnect the hose couplings i Connect your BLUE link hose supplied to the pure water outlets marked Pure 1 Pure 2 on the PURE water outlet to the hose reel or directly to waterfed pole If you have a static hose reel mounted in the vehicle it will already be connected ready for use ii Switch the flow controller on by pressing the button iii You can adjust the w...

Page 12: ...do this lift the brush away from the glass and move the head from side to side working from top to bottom motion allowing the water remove all particles from the glass If you are cleaning windows on a warm day the rinsing procedure must be done meticulously as warm direct sunlight can cause spotting due to insufficient rinsing The SMARTANK system is designed for a single or double operator use Ope...

Page 13: ...tre dE A dead end has been detected The pump has been turned off automatically by the controller as there is a water stop somewhere in the system PS The pressure switch has been activated This means the pressure has exceeded the pressure switch rating Check if there is no water blockage or reduce the pump speed to lower the resistance Bat Pump still working Your battery voltage has dropped below 1...

Page 14: ...the SMARTANK system to ensure all filters are adequate and effective for producing pure 000ppm water quality Keep a check on the pure water TDS by using the handheld TDS meter This measures in parts per million ppm If the output reads higher than 3ppm it is recommended to change the de ionising DI filter and make a note in the back of the inspection booklet Keep a check on the battery voltage by r...

Page 15: ...ppm a replacement RO membrane is needed 2 The second TDS meter is mounted on the front of the SMARTANK cabinet which monitors the water purity of both DI filters operator 1 operator 2 If the final water reading is above 5ppm a replacement DI filter is needed Prefilters usage and replacing The prefilter set are the first initial filter set the feed water will pass through Usage Either quarterly repl...

Page 16: ...l immediately Reverse Osmosis RO Membrane Filters usage and replacing The RO membranes are the core part of the water filtration produce up to 98 of water filtration After you have replaced a new RO membrane filter ensure you complete a backwash before the membrane is put under pressure Usage Either yearly replacement or approx 250 000ltrs of pure water running through whichever comes quickest How...

Page 17: ...to run intermittently To avoid this happening make sure that the pump speed is correctly set on the flow controller The pump must not be stored under pressure as this will invalidate the warranty PRODUCT CODE 8000 946 238 7 8 Disposing of filters and machine Declaration of conformity Dean Scott Development Director 9 Why STREAMLINE STREAMLINE systems can be built according to customers exact requir...

Page 18: ...issued upon subsequent inspection and warranty approval by STREAMLINE The customer is responsible for the cost of return of the defective part If warranty is approved STREAMLINE will pay for the cost of the repaired or replacement part This warranty excludes the following conditions and circumstances which are at the discretion of STREAMLINE Wear and tear misuse abuse improper maintenance frost da...

Page 19: ...Hamilton House 8 Fairfax Road Heathfield Industrial Estate Newton Abbot Devon TQ12 6UD United Kingdom Telephone 44 0 1626 830 830 Email sales streamline systems Visit www streamline systems INSTR SMT ...