background image

Dimension

179mm

30 mm

21 mm

Applications

-Use in damp and dry environment.
- For use on a wide range of LED fittings to convert them from standard 
  to emergency fitting.
- LED fitting would be maintained emergency fitting if standard 
  (main powered) driver, emergency lighting kit and battery are all retained 
  in the circuit. LED fitting would be non-maintained emergency fitting 
  if only emergency conversion module and battery are retained in the circuit.
- Additional Relay that can control standard LED driver.
- Deep discharge protection.
- Connector between emergency kit and battery has the function of 
  polarity reversal  protection.
- Ambient range  ta 0....50

 

- IP20 protection, relies on end-product enclosure for protection against 
  accidental contact live parts. 
- Not intended for use in luminaries for high-risk task area lighting.
- Full warranty 3 years.

Relevant standard

IEC 61347-1
IEC 61347-2-7
EN 62034
EN 55015
EN 61547
EN 61000-3-2
EN 61000-3-3
EN 62493
AS/NZS 60598-2-22
AS2293.3

Product description

- Self-test function.
- LED emergency converter that can transfer standard LED fitting into 
  emergency LED fitting. 
- Used with Lithium iron phosphate battery.
- Suits for LED fitting with external led driver.
- Accessary: test switch and charge indicator.

180min

LVLE

220-240

18

YH18 Series  Self-test

 

LED Emergency converter

1/6

Data sheet 02 / YH18 Basic self-test

 

Summary of Contents for YH18 Series

Page 1: ...ry has the function of polarity reversal protection Ambient range ta 0 50 IP20 protection relies on end product enclosure for protection against accidental contact live parts Not intended for use in luminaries for high risk task area lighting Full warranty 3 years Relevant standard IEC 61347 1 IEC 61347 2 7 EN 62034 EN 55015 EN 61547 EN 61000 3 2 EN 61000 3 3 EN 62493 AS NZS 60598 2 22 AS2293 3 Pr...

Page 2: ...rmally after reconnecting of battery YH18 Series Self test LED Emergency converter YH18 2 03 1050 Li Nomenclature Emergency power kit 1 Basic series 2 Power Emergency mode 3 Duration 4 Output voltage Emergency mode 5 Battery YH18 2 2W 3 3W 4 4W 03 180minutes 1050 10V to 50V H200 50V to 200V Li LiFePO4 Battery 1 2 3 4 5 Naming rules Ordering data Type YH18 2031050Li YH18 203H200Li YH18 3031050Li YH...

Page 3: ...e Neutral Neutral Un switched supply Un switched supply Switched supply YH18 Series Self test LED Emergency converter Installed on the back of the panel requires safety and fixation Only professional people e g electrical Engineer can wire it Please confirm that the electrical parameters of this product match with the luminaire Please check the wiring method carefully before installation Please powe...

Page 4: ... 2 Model No Rated Type Number of cells Battery cells type YHBL 2 1 5B YHBL 2 1 5Z YHBL 2 2 2 YHBL 2 3 0 YHBL 2 1 5B YHBL 2 2 2 YHBL 2 3 0 YHBL 2 1 5Z 90 36 23mm 3 5 1 4 0 9 160 20 23mm 6 3 0 8 0 9 130 36 23mm 5 1 1 4 0 9 160 36 23mm 6 3 1 4 0 9 IFR18650 1500 IFR18500 1100 IFR18650 1500 IFR18650 1500 6 4V 1 5AH 9 6Wh 6 4V 2 2AH 14 4Wh 6 4V 3 0AH 19 2Wh 6 4V 1 5AH 9 6Wh IFR18650 1500 2s1p IFR18500 1...

Page 5: ...ttery Battery operation emergency mode Function test underway Duration test underway Color Green Red Red Green Green Status Comment AC mode SelfTest The emergency kits carry out self tests automatically to ensure its functionality The self test includes 3 types of tests Initial test As soon as mains supply is connected the emergency kit will carry out a 3 seconds functional test automatically In c...

Page 6: ...tinuous charging time can not exceed 3 months Warranty Warranty 3 years Except for the following circumstances 1 Improper installation or operation 2 Misuse 3 Abuse 4 Unauthorized or improper repair alteration 5 Accident or negligence in use storage transportation 6 Any natural acts If users would like to change the batteries pack please use the nominated models of STREAMER then it will be under t...

Reviews: