background image

User manual for X3-H0402

For more information, please visit our website

www.en.streamax.com

11-71

SERIAL PORT DEFINITION

Summary of Contents for X3-H0402 MDVR

Page 1: ...l for X3 H0402 For more information please visit our website www en streamax com 1 71 User Manual For X3 H0402 MDVR Mobile Digital Video Recorder Copyright 2013 2015 Streamax Technology Co Ltd All Rights Reserved ...

Page 2: ...otice The purpose of this manual is to kindly aid the user for the operation for our MDVR The user should have a basic understanding of computer operation and basic knowledge of how to connect peripherals and make some settings Copyright Under copyright laws the content of this manual may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form i...

Page 3: ...ts on Engineers Technicians All the work of checking and maintenance should be done by qualified technicians and engineers We do not undertake any responsibility caused by unauthorized modifications 5 Requirements on Environment The equipment should be installed and stored in a cool and dry place away from direct sunlight flammable or explosive substances etc Keep gaps not less than 3cm around the...

Page 4: ... 20 2 5 BASIC SETUP 22 2 5 1 REGISTER INFOMATION SETUP VEHICLE INFORMATION 22 2 5 2 TIME SETUP 24 2 5 3 START UP 26 2 5 4 USER SETUP 27 2 5 5 NETWORK 28 2 5 6 APPLICATION 32 2 6 SURVEILLANCE 32 2 6 1 LIVE VIEW 33 2 6 2 RECORD 34 2 6 3 IPC SETUP 38 2 6 4 PTZ 40 2 7 DATA COLLECTION 40 2 7 1 GENERAL 40 2 7 2 SNAP SETTING 42 2 7 3 ECO DRIVING 44 2 8 ALARM 45 2 8 1 BASE 45 2 8 2 VIDEO 52 2 8 3 ADVANCE ...

Page 5: ...ation please visit our website www en streamax com 5 71 3 4 MAINTENANCE 64 3 4 1 BASIC INFORMATION 65 3 4 2 DEVICE MODULE 65 3 4 3 STORAGE DEVICE 66 3 4 4 VERSION INFORMATION 67 3 5 CONFIGURATION 67 4 STORAGE CAPACITY CALCULATION 69 5 FAQ 70 ...

Page 6: ...e installation and high reliability 1 2 SPECIFICATIONS Function Overview Preview Recording Playback Network Locating System OS Linux 3 0 8 Control Mode CP4 Easy Check network mouse Video Input 4 channels WD1 2 channels 720P Output 1 channel Total Resource 4 x 25 FPS WD1 PAL 4 x 30 FPS WD1 NTSC 2 x 30 FPS 720P Video Signal Standard Electrical level 1Vpp Impedance 75Ω NTSC PAL Optional Audio Input 6...

Page 7: ...speed detection and time sync Storage Hard Disk 2 5 SATA hard disk x 1 Up to 2 TB Interface USB USB2 0 2 One for Easy Check one for external mirror recording SD SD 1 SIM SIM x 1 RS232 RS232 2 RS485 RS485 2 Sensor 8 inputs 2 outputs Serial G sensor Internal Speed 1 channel pulse speed detection Interface Control panel CP4 Optional Intercommunication I MIC interface Power Input DC8 36V Output 5V 100...

Page 8: ...User manual for X3 H0402 For more information please visit our website www en streamax com 8 71 1 3 SYSTEM DIAGRAM 1 4 EXTERNAL INTERFACE DIMENSION Unit mm ...

Page 9: ...1 Hard disk module 2 Status LED 3 USB interface REAR PANEL Serial No Print Description 1 Power DC 8 36 V Power Input 2 Sensor Serial The Interfaces of Serial Port and Switch 3 A V IN1 4 Audio Video Input 1 4 4 A V OUT Audio Video Output 5 IPC The Interface of PON Power Supply 6 GPS Antenna Interface 7 3G 4G WIFI Antenna Interface ...

Page 10: ...User manual for X3 H0402 For more information please visit our website www en streamax com 10 71 1 5 HARD DISK INSTALLATION 1 6 DEFINITION AND PICTURES OF EXTERNAL CABLES ALARM CABLE DEFINITION ...

Page 11: ...User manual for X3 H0402 For more information please visit our website www en streamax com 11 71 SERIAL PORT DEFINITION ...

Page 12: ...obile DVR to have MDVR parameter setting RS232 serial port is needed when they are model X1 and M1 while model X3 X5 and X7 can connect to the panel interface directly 3 Model X5 supports MDVR parameter setting via remote controller 2 1 LOGIN INTERFACE When operate the device user needs to have permission certified 1 Press the remote control LOGIN LOCK or SETUP the login screen will pop up 2 Right...

Page 13: ...e right password 2 User must enter the right password again if entering the wrong ones 3 Click cancel to exit the login interface Language 1 It supports language switch language Lang means the current interface adopts Chinese 2 It will automatically switch once selecting the language 3 Currently it supports Chinese and English 4 After switching languages it will not restore language option when us...

Page 14: ...eans numbers AB means capital letters the highlighted place of background refers to the current cursor position 5 Move Cursor to Press Enter or left click mouse to move between the contents that have entered 6 Move Cursor to Press Enter or left click mouse to delete the previous input contents 7 Move Cursor to Press Enter or the left click mouse to exit the keypad the entered contents will be writ...

Page 15: ...rd enter the video search interface Following is the REC Search interface In the calendar the color below the dates means a No color means no video b Green means common video c Red means alarm video d Yellow means there are alarms and the video files are automatically lock lock video Source select the source of the video there are main video sub video and mirror video The main record means HDD rec...

Page 16: ...nt relates Click search button in the record search detail page user can enter then record search result page Time Bar Time bar shows three time points 0 o clock 12 o clock 24 o clock It shows what type of videos during the time according to the marked channel Channel No According to the situation of video for each channel video the day the video will be displayed on the time line Tick the channel...

Page 17: ... the time setting button select start time and end time it will back up or playback the video in the selected time period Click clip to export the video the file format can be 264 comprehensive file also can be avi format Video export Select the channel that has the video files click this button all the video files in the effective time period will be exported to the external USB peripherals file ...

Page 18: ...arch interface it records and displays all alarm events and login operation log Enter the log query the interface will be shown as following Log Search interface instruction Calendar the date with log will be marked on the calendar with green color Remark There is no color classification in the log mark and all are green ones ...

Page 19: ...of log search including the operation log and alarm log and locking log Operation log search interface instruction Log includes the following information Log time the time when event is triggered Log name event content Supports page up page down and export all log files of the specified date Do not support link to video file Log search Alarm type It includes all alarms IO alarm panic alarm and ove...

Page 20: ...nt triggered Log name event content Log will be recorded according to channel number each channel will have a lock log file Support page up and page down Can t export all log files of the specified date Can link to video file click on button to playback video files Unlock Select log and unlock it Then the alarm log of lock will be cleared Remark When lock the video file system will record alarm lo...

Page 21: ...User manual for X3 H0402 For more information please visit our website www en streamax com 21 71 System Server status System Environment ...

Page 22: ...e information please visit our website www en streamax com 22 71 System Storage 2 5 BASIC SETUP Click setup button and enter the following interfaces 2 5 1 REGISTER INFOMATION SETUP VEHICLE INFORMATION Register information Device info ...

Page 23: ...r website www en streamax com 23 71 Device ID Currently it is not useful Register information Vehicle info Vehicle Number When connected with PAD the vehicle number is needed Vehicle plate Input manually Line number Input manually Register information Driver info ...

Page 24: ...ebsite www en streamax com 24 71 Driver number Input manually Driver name Input manually 2 5 2 TIME SETUP Time setup General Date format Setup the date format of device Time format 24 hours or 12 hours Time zone Range from 12th district 13th district Time Time Sync ...

Page 25: ...to valid device will synchronize time Center Server synchronize time with center server NTP sync synchronize time with NTP server Remark 1 Synchronize time according to time zone 2 Multi mode can be selected for time synchronization If one works the others take no affect Otherwise it switches to another sync mode every 5 minutes Time setup DST Enable Select to enable Offset After enabling DST adju...

Page 26: ... ignition timer and ignition or timer Ignition Input ignition delay time for shutdown delay function Timer When setup the start mode as Timer please setup the start time and end time Under this mode MDVR s start up or shut down time will not affect the ignition Remark If use setup as Ignition or Timer Mode Ignition ON or Timer start time can trigger MDVR start up And only when Ignition off and Tim...

Page 27: ...ndard value it will countdown shutdown As for a 12V vehicle the default is 9V while a 24V vehicle is 21V Voltage start up low voltage protection when the battery voltage is consistently greater than the standard value it will automatically boot As for a 12V vehicle the default is 12 5V while a 24V vehicle is 24 5V Low volt upload The low voltage protection will be reported to the platform after it...

Page 28: ...r the following interface Remark 1 Only administrators can add users 2 Users can add up to two 3 User name cannot be empty not the same with the existed user name while the user password can be empty User name and password can be modified Select a user click the Edit User button enter the following interface Modify the user name and password to confirm the operation temporarily There is no need to...

Page 29: ...statically configured to dynamically obtain Use the following IP Static IP need to use a static DNS Remark Switch from static IP to automatically obtain IP mode it can display dynamic IP but the static IP parameters will not be covered to restore the last saved static IP after switching back Network Settings Ports WEB port No The default is 80 Network WIFI ...

Page 30: ...use static IP or MDVR will get dynamic IP Network Communication Dialing wireless network user needs to choose the module type and setup dialing parameters When entering the dialing setup interface it searches the wireless module type automatically It shows No Service when there is no module Network type The default one is Mix 2G 3G and 2G 3G 4G optional Dialing parameter It includes access point u...

Page 31: ...G 4G signal it will dial automatically Network Server Center server It supports 6 servers at most and server 1 cannot be deleted manually ON Enable the current server Protocol type The default one is N9M Enable network There is local WIFI and module optional Register server address To run the registration server address Registration server port To run the registration server port Media server addr...

Page 32: ... our website www en streamax com 32 71 2 5 6 APPLICATION Application FTP Client FTP Enable Enable FTP Server To run FTP server address Port To run FTP server port The default one is 21 User name password The accounts distributed by FTP server 2 6 SURVEILLANCE ...

Page 33: ...dio Enable the audio when live view the video Image setup Set the live view parameters including brightness contrast etc Startup Screen Set the live view screen it can be single screen or quad screen or nine screen Channel Set the channel when live view Live view Auto Loop Screen Totally 32 screens can be added Mode 1x1 2x2 3x3 optional Channel Included channel number ...

Page 34: ...each screen Edit Delete or Edit Add screen Add polling screen Auto polling Enable the auto pulling Live view Live OSD It displays the information on screen such as time speed license plate GPS The default is only the time and the position cannot be set 2 6 2 RECORD Record General Video type Default is PAL NTSC optional ...

Page 35: ...1 Overwrite The earliest recording file will be deleted while the HDD or SD card is full to realize loop recording Lock duration Protect the record file to be deleted by fault default is 7 days Pre recording Pre record before the alarm happens Default is 15min 0 60min optional Record Main Stream ...

Page 36: ...while the digital one supports 720P Frame Rate Frame Rate of the recording Quality Picture Quality of the recording Record mode Ignition Time Event optional Each channel can be set separately The sub stream and mirror record are the same Audio Enable the audio Note Audio cannot be record separately I frame Enable to let the frame rate invalid record file that does not have alarm is I frame only Al...

Page 37: ...ub stream Mirror record Channel is selectable Video resolution and frame rate are the same with main stream Alarm backup Channel is selectable The parameters are the same with main stream Sub stream Channel is selectable Recording parameters are configurable Sub stream includes channel number enable or not audio resolution frame rate and image quality Sub stream channel It is selectable according ...

Page 38: ...User manual for X3 H0402 For more information please visit our website www en streamax com 38 71 Embedded key information to video file for easily check when playback 2 6 3 IPC SETUP IPC setup ...

Page 39: ...t be shown if it connects to network camera Enable Enable to operate IPC IP and port Display channel details after searching Setup Search and edit IP camera recording parameters Fast setup Search all the IP cameras in LAN network and auto assign IP address to IP camera IPC local address To search network camera of local area network at Intranet The default one is 10 100 100 1 ...

Page 40: ...des analog channels and IPC channels Enable Enable PTZ Operate It includes serial N9M and ONVIF It supports Pelco D and Pelco P PTZ protocols with serial mode Address It is valid with serial mode Test It is to test PTZ is available or not Click it to pop up PTZ control panel 2 7 DATA COLLECTION 2 7 1 GENERAL General Sensor ...

Page 41: ...rm setting interface will update synchronously after setting OSD name The information embedded to video image Copy Copy the configuration and use it for other sensors General Serial port RS232 1 and RS232 2 with the following features three axis sensor expansion 485 bus and GPS data RS485 1 and RS485 2 with the following features PTZ control panel 485 bus and GPS data Baud Rate 2400 115200 9 class...

Page 42: ...l M1 and X1 equip only one RS232 port but it can realize the following features expansion control panel 485 bus GPS data three axis sensor PTZ and integrated printer General speed Unit KM H and MPH selectable Source GPS pulse or both optional Calibration mode No need to calibrate if setup as satellite mode 2 7 2 SNAP SETTING Snap Setting Time snap ...

Page 43: ... please visit our website www en streamax com 43 71 Start time Start to snap End time Stop snapping Setup Delete and set Time snap Enable to snap at the setting time Add To add snap period and it supports 8 pieces at most Snap Setting Trigger snap ...

Page 44: ...User manual for X3 H0402 For more information please visit our website www en streamax com 44 71 Trigger snap It snaps when alarm is trigger 2 7 3 ECO DRIVING It is still developing ...

Page 45: ...User manual for X3 H0402 For more information please visit our website www en streamax com 45 71 2 8 ALARM 2 8 1 BASE Base Speed alarm ...

Page 46: ...es the following types important and general Trigger Over speed pre alarm difference To set the pre alarm data For example if speed is 60 km hour and over speed pre alarm difference is 10 km hour TSS sends over speed alarm broadcast and records when it reaches 50 km h Speed It is the alarm speed Alarm duration Alarm output duration Linkage When alarm triggered link to other business operation ...

Page 47: ...gger dial mode it enables 3G network as it triggers alarm Linkage IO output Enable to link alarm output when alarm is triggered Output delay time It means the alarm output duration after alarm is removed Alarm upload Enable to upload to platform Linkage screen Enable to link the channel to show full image when there is alarm Depends on the MDVR model display split 1 4 9 optional PB alarm duration ...

Page 48: ...n streamax com 48 71 Name The current name is panic Enable Enable to panic button Alarm type Important type and general type optional Trigger Click any button to delay the time till it reaches the setting time to alarm Linkage When alarm is triggered link to business operation ...

Page 49: ...ensor trigger dial mode it enables 3G network as it triggers alarm Linkage IO output Enable to link alarm output when alarm is triggered Output delay time It means the alarm output duration after alarm is removed Alarm upload Enable to upload to platform Linkage screen Enable to link the channel to show full image when there is alarm Depends on the MDVR model display split 1 4 9 optional PB alarm ...

Page 50: ...IO alarm interface Name From Sensor1 to Sensor8 It includes all the alarm input numbers Enable Enable the sensor alarm Alarm type Important type and general type optional Trigger Low and high optional It triggers alarm when it is low as default Linkage When alarm is triggered link to business operation ...

Page 51: ...ensor trigger dial mode it enables 3G network as it triggers alarm Linkage IO output Enable to link alarm output when alarm is triggered Output delay time It means the alarm output duration after alarm is removed Alarm upload Enable to upload to platform Linkage screen Enable to link the channel to show full image when there is alarm Depends on the MDVR model display split 1 4 9 optional PB alarm ...

Page 52: ... For more information please visit our website www en streamax com 52 71 2 8 2 VIDEO Video Video loss Name The default name is video loss Enable Enable the video loss Alarm type Important type and general type optional Trigger ...

Page 53: ... please visit our website www en streamax com 53 71 Video loss set It includes all video channels that can be selected Set period Set the checking period when video loss alarm is triggered Linkage When alarm is triggered link to business operation ...

Page 54: ...ensor trigger dial mode it enables 3G network as it triggers alarm Linkage IO output Enable to link alarm output when alarm is triggered Output delay time It means the alarm output duration after alarm is removed Alarm upload Enable to upload to platform Linkage screen Enable to link the channel to show full image when there is alarm Depends on the MDVR model display split 1 4 9 optional PB alarm ...

Page 55: ...formation please visit our website www en streamax com 55 71 2 8 3 ADVANCE Name The default name is ACC alarm Enable Enable the ACC alarm Trigger Set the threshold value of X Y Z Linkage When alarm is triggered link to business operation ...

Page 56: ... network as it triggers alarm Linkage IO output Enable to link alarm output when alarm is triggered Output delay time It means the alarm output duration after alarm is removed Alarm upload Enable to upload to platform Linkage screen Enable to link the channel to show full image when there is alarm Depends on the MDVR model display split 1 4 9 optional PB alarm duration It means the available alarm...

Page 57: ... the configuration file Insert flash drive to export the configuration file to the root folder the file name is ConfigFile Insert flash drive to import configuration file into MDVR and it will display the notice when import successfully Remark It won t import the register info and speed adaption info 2 9 2 DATA EXPORT User can export any file File type GPS data file vehicle info file ACC info file...

Page 58: ...de software Put the upgrade file in flash drive Currently device firmware microcontrollers firmware CP4 firmware and IPC firmware can be put inside Insert flash drive and enter the upgrade interface click software upgrade and it will indicate that upgrade file is importing MDVR reboot up and enter into upgrade interface after importing successfully ...

Page 59: ... 15 jpg and logo_cvbs 11 12 15 jpg 6 Please don t put many files in the same folder when it is upgrading otherwise it will upgrade one randomly 2 9 4 STORAGE In this page user can format all the storage Storage type HDD SD card Internal SD card External USB drive Free Total Not exist Didn t find the HDD not install or broken Unformatted Means the HDD has been detected but unformatted New HDD Capac...

Page 60: ...ver info speed adaption parameter will not change during default settings 3 WEB MANAGEMENT 3 1 LOGIN INTERFACE 1 Connect MDVR into local area network set relevant information to make sure the computer can visit the MDVR 2 Open browser and input http IP address of MDVR It will go to the WEB login interface of MDVR And the default IP address is 192 168 1 100 3 Interface will pop up a window to insta...

Page 61: ...User manual for X3 H0402 For more information please visit our website www en streamax com 61 71 3 2 MAIN INTERFACE ...

Page 62: ...e visit our website www en streamax com 62 71 Icons quad 9 split preview next page sound capture and video parameters Stream switch main stream sub stream and network transmission sub stream Log out log out and come to the log in interface 3 3 PLAYBACK ...

Page 63: ...User manual for X3 H0402 For more information please visit our website www en streamax com 63 71 If the date is marked as color green it means there is recording ...

Page 64: ...ase visit our website www en streamax com 64 71 Recording playback window Video window play time line play control button window switch Record list It displays all the record Click backup download video file to local computer hard disk 3 4 MAINTENANCE ...

Page 65: ...website www en streamax com 65 71 3 4 1 BASIC INFORMATION Basic information It contains the current state history state of channel video and storage 3 4 2 DEVICE MODULE Device module It is about the current state of module WIFI module and satellite location module ...

Page 66: ... more information please visit our website www en streamax com 66 71 3 4 3 STORAGE DEVICE Storage device There are the volume information format operation of storage hard disk flash drive SD card and the path of snap record backup ...

Page 67: ...rsion information There are device type name firmware version MCU version CP3 4 version upgrade configuration file export and configuration file import Log Log There is Log type operation log alarm log and locked log operation type IO alarm panel alarm speed alarm video loss and ACC alarm date and log export 3 5 CONFIGURATION ...

Page 68: ...User manual for X3 H0402 For more information please visit our website www en streamax com 68 71 The parameter setting is the same as the local setting User can view the operation at the local setting ...

Page 69: ...0 960 768 640 560 500 450 400 CIF 800 600 480 400 350 312 280 250 2 Record File Size Calculation Rec file size for each channel is Recording time s x Stream Kbps 8 1024 File Size MB e g The file size of the Image 1 with D1 resolution within 1 hour 3600 x 2048 Kbps 8 1024 900 MB 3 Image Quality Resolution Resolution Image quality 1 2 3 4 5 6 7 8 Record MB 720P 2700 2109 1814 1518 1223 928 632 337 W...

Page 70: ...s formatted The storage disk should be formatted before normally storing record files 3 Check whether there is video signal input into the device from camera and whether there is video image on the screen 4 There is no voice in record file Please follow below steps to check it 1 Check whether there is an external pickup or whether the camera features with the function of audio collection 2 Access ...

Page 71: ...ord Make sure the storage part is installed and of fine contact the data can be read on PC and the storage device is not formatted Check if there are video signal input to the main device and whether there are video images in the channel pictures 13 Why has the MDVR device always been in a state of restart Check whether the MDVR device voltage is insufficient If the device voltage does not reach t...