background image

OPERATING INSTRUCTIONS

 

MODEL PRH-09THD

 

PRESSURE REDUCING VALVE

 

APPLICATIONS: 

Valve should only be used for non-corrosive fluids, or where 
the materials selected are compatible with the fluid and will 
not  cause  corrosive  buildup,  which  could  keep  the  main 
valve  from  opening.  When  liquids  contain  debris  or  other 
solid matter, which might cause internal clogging or improp-
er  operation  of  the  valve,  a  strainer  with  a  fine  wire  mesh 
should  be  installed  before  the  inlet  of  the  valve.  In-line 
strainer  fittings  or  basket  strainers  can  be  purchased  from 
STRA-VAL to solve this problem. 

Do not use this valve as 

a shutoff valve

, even though the valve, when new, is able 

to do so. In time as wear sets in, seat leakage may increase 
and result in an objectionable pressure rise at zero flow. As 
long  as  the  flow  through  the  valve  is  greater than  the  seat 
leakage, the valve could still regulate. 

PRINCIPLE OF OPERATION 

Phone:  973-340-9955                             Fax:  973-340-9933 
http://www.straval.com                          Email: [email protected]

 

When the valve is shipped from the factory it is usual-
ly  ready  for  operation.  On  larger  valves,  all  that  may 
be  required  is  to  install  the  adjusting  screw  if  it  is 
strapped to the spring chamber and make a final pres-
sure adjustment at the final operating conditions. This 
step is not required if the valve is ordered preset for a 
specific pressure setting and so marked 

Check  to  make  sure  that  the  discharge  piping  is  not 
blocked  off  and  that  the  valve  does  not  operate 
against a shut-off condition. Check to make sure there 
is no visible leakage coming from the spring chamber. 
This would occur if the packing nut is set too loose or 
if the packing rings take a slight set. A simple adjust-
ment of the packing nut by 1/6 or 1/4 turn is normally 
sufficient. This would have to be done with the spring 
chamber removed If after extensive use the valve be-
gins to lose its ability to regulate, or if there is exces-
sive seat leakage due to wear, which would cause  an 
excessive  pressure  rise  on    the  outlet  side  of  the 
valve,  or  if  there  is  external  seal  leakage,  the  valve 
will require parts to be replaced and  

the valve sent in for possible repair. Before removing 
the valve from service 

Make sure that the valve is 

isolated  from  the  piping  completely  in  order 
avoid any personal injury  

Usually,  only  the  v-packing  rings  will  require  replace-
ment.  However,  if  there  is  excessive  seat  leakage, 
then the main valve may  also require replacement or 
just  a  minor  re-cutting  of  the  seating  surfaces.    With 
the  valve  removed  from  service,  a  quick  test  for  me-
chanical operation is to see if the 

main valve is free 

to  move  by  hand

.  This  should  be  done  with  the 

spring chamber removed. If the main valve is 

not

 free 

to move, 

the packing nut is either too tight

 or the 

main valve is frozen in place or worn, and will there-
fore need to be disassembled. 

MAINTENANCE & REPAIR 

Fluid passing through the valve enters through the inlet port 
through the valve seat formed by the main valve and seat, 
and finally through the outlet port. Outlet pressure is sensed 
by the underside of the piston, which is able to move up and 
down with changes in outlet pressure.  Pressure regulation is 
achieved  when  a  force  balance  is  maintained  between  the 
pressure  acting  on  the  underside  of  the  piston  and  the 
spring  force,  which  is  adjusted  to  hold  a  particular  outlet 
pressure.    If  the  outlet  pressure  is  below  the  set  point, 
which  is  preset  by  the  adjusting  spring,  the  spring  force 
overcomes the pressure force acting on the underside of the 
piston. This causes the main valve to open, thereby admit-
ting  higher  inlet  pressure  fluid  to  raise  the  outlet  pressure 
until  the  force  balance  is  restored.  As  soon  as  the  outlet 
pressure is restored, the main valve begins to close to limit 
the  amount  of  higher  inlet  pressure  fluid  passing  through 
the valve  

DISASSEMBLY / ASSEMBLY INSTRUCTIONS 

To disassemble the valve, it is best to remove the 
valve from the piping, since it is more convenient to 
work on the valve on a bench with a vise.  Unscrew 
the spring chamber with a wrench in the area provided 
with wrench flats. With the spring chamber off, the 
packing nut may be removed and the Teflon v-packing 
rings extracted. Make sure the valve is not under 
pressure if it is still in the line. Be sure not to damage 
them as they perform a critical sealing function.  If 
they are damaged or worn they need to be replaced.  
When reinstalling the v-packing rings, make sure that 
they are properly installed as shown in the illustration 
with the open part of the “v” facing the pressure side.  