Service and maintenance
150
Sherpa 120, 140 | 06.19
9.9
Check and top up central lubrication
As a basic principle, the following is applicable:
•
Only use lithium-saponified multi-purpose grease of NLGI
class 2.
•
Only use grease of the same saponifying criteria.
•
Lift ed
Operative staff:
•
Operator
1. Check the level in the reservoir (1) before each use.
–
The level must not fall below 1 cm.
–
Top the reservoir up early enough.
2. Top the reservoir up only through the lubricating nipple
(3) if necessary.
–
Ensure utmost cleanliness.
–
Keep the cover (2) always closed, thus ensuring that
the grease is permanently protected against the
entry of water.
3. Regularly check the feed lines to the lubrication points for
damage or break-off.
Fig. 106