Operation
161
Giga-Vitesse CFS 3602 - 4402, Giga-Vitesse CFS 3602 DO - 4402 DO 03.18
6.1.6
Operating hours counter, service hours counter and transported loads
counter
•
The daily operating hours counter and the daily transported
loads counter can be reset at any time.
•
The daily operating hours counter and the daily transported
loads counter are not automatically reset every day. These
counters must be reset manually.
•
The total service hours counter, the total operating hours
counter and the total transported loads counter cannot be
reset.
The operating hours counter and the transported loads counter are designed each as daily and total
counters. The service hours counter is designed as total counter.
•
Daily operating hours counter (operating hours until reset (h)). The operating hours of the
machine during which the pick-up is in lowered position are registered.
•
Daily transported loads counter (transported loads until reset). The number of transported loads
is registered by counting the number of opening cycles of the tailgate.
•
Total operating hours counter. The total operating hours counter registers the overall period of
use of the machine during which the pick-up is in lowered position.
•
Total service hours counter. The total service hours counter registers the overall period of use
of the machine by registering the time during which the ISOBUS control set is in switched-on
mode.
•
Total number of transported loads counter. The total number of transported loads counter
registers the number of transported loads during the overall period of use of the machine.
6.1.7
Call up Counter menu
The total service hours counter is displayed in the
SET
menu.
1.
Briefly press the
key once.
The
Counter
appears:
(1)
Total operating hours counter
(2)
Total transported loads counter
(3)
Daily operating hours counter
(4)
Daily transported loads counter
2.
Press the
key once.
The
Working
menu appears.
The screen shows:
Summary of Contents for Giga-Vitesse CFS 3602
Page 2: ......
Page 4: ...Bad Laer den 26 03 2018 Dipl Kfm W Strautmann Managing Director...
Page 306: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 306 Fig 174...
Page 309: ...Circuit diagrams 309 Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18...
Page 310: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 310...
Page 313: ...Circuit diagrams 313 Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18...
Page 314: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 314...
Page 317: ...Circuit diagrams 317 Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18...
Page 318: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 318...
Page 320: ...Circuit diagrams Giga Vitesse CFS 3602 4402 Giga Vitesse CFS 3602 DO 4402 DO 03 18 320...
Page 326: ......