background image

4

It is your responsibility to:
•  Regularly inspect and make necessary repairs to compressor in order to maintain 

proper operation

•  Make sure that pressure is released from compressor before starting maintenance
Check intake and exhaust filters after first 500 hours of operation. Clean filters and deter-

mine how frequently filters should be checked during future operation. This one proce-

dure will help to assure the product’s performance and service life.
1  Disconnect electrical power supply to unit

2  Vent all air lines

3  Remove filter cover

4  Check filter felt. Replace felt if it is covered with contamination or shows signs of 

increasing differential pressure

5  Reinstall felt and filter cover
Check that all external accessories such as relief valves and gauges are attached to 

cover and are not damaged before re-operating product.

SHUTDOWN PROCEDURES:

It is your responsibility to follow proper shutdown procedures to prevent compressor 

damage. Never add oil to this oil-less compressor.
Proper shutdown procedures must be followed to prevent pump damage. Failure to do 

so may result in premature pump failure. Compressors are constructed of ferrous metals 

or aluminum which are subject to rust and corrosion when pumping considerable vapors 

such as water. Follow the steps below to assure correct storage and shutdown between 

operating periods.
1  Disconnect plumbing

2  Operate compressor for at least 5 minutes without plumbing

3  Run at maximum vacuum for 10 to 15 minutes

4  Repeat step 2

5  Disconnect power supply

6  Plug open ports to prevent dirt or other contaminants from entering compressor

SRC25/SRC50 REPAIR KIT INSTALLATION:

 

WARNING! Electrical Shock Hazard. Disconnect electrical power supply 

before installing repair kit. If product is hard wired into system, discon-

nect electrical power at the circuit breaker or fuse box before installing repair kit. Vent all 

air lines to release pressure or vacuum. Failure to follow these instructions can result in 

death, fire, or electrical shock.

EasyPro will not guarantee field-rebuilt compressor performance. For performance 

guarantee, the compressor must be returned to EasyPro.

Repair kit contents may vary.

1  Remove screws from the head of compressor using T25 Torx driver, remove the head.

2  Mark the orientation of head plate(s) and remove.

3  Remove old cylinders and discard.

4  Remove screws from cup retainer plate with T15 Torx driver. Discard old cups and 

retainer screws.

5  Set new cylinder(s) on piston(s).

(continued on next page)

Summary of Contents for SRC25

Page 1: ...s exhaust air can become very hot Corrosive gases and particulate material will damage unit water vapor oil based contaminants or other liquids must be ltered out Product performance changes when usin...

Page 2: ...flow through pump MOTOR CONTROL It is your responsibility to contact a qualified electrician and assure that the electri cal installation is adequate and in conformance with all national and local cod...

Page 3: ...at If in doubt use the next heavier gage cord The smaller the gage number the heavier the wire gage OPERATION WARNING Injury Hazard Install proper safety guards as needed Keep fingers and objects away...

Page 4: ...ed of ferrous metals or aluminum which are subject to rust and corrosion when pumping considerable vapors such as water Follow the steps below to assure correct storage and shutdown between operating...

Page 5: ...he valve plate s with ports is correct and place over cylinders 11 Remove old and install new head o rings in the o ring grooves on top of valve plate 12 Reinstall head over valve plate s checking tha...

Page 6: ...nd Belt Cap 12 Cylinder O ring 13 Screw 14 Fan Clockwise 15 Pipe Plug 16 Filter 18 Valve Plate 19 Leaf Valve 20 Valve Limiter 21 Valve Screw 22 Valve Screw 23 Valve Retainer 25 Bearing 26 Cup 27 Retai...

Page 7: ...et Screw 10 Fan 11 Pipe Plug 13 Valve Plate 14 Leaf Valve 15 Valve Limiter 16 Valve Screw 17 Leaf Valve 18 Valve Screw 19 Valve Retainer 20 Plug 22 Bearing 23 Cup 24 Retainer Plate 25 Eccentric 26 Rod...

Page 8: ...crews cylinder O ring s head O ring s and inspect valves and valve retainers If leaf valves need to be replaced a complete leaf valve plate is included step 12 The screws holding the leaf valves are s...

Page 9: ...Retainer 7 Leaf Valve 8 Valve Plate 9 Tube O Ring 10 Valve Screw 11 Cylinder O Ring 12 Cylinder 13 Retainer Screw 14 Retainer Plate 15 Piston Cup 16 Rod Assembly 17 Shroud 18 Fan 19 Shroud Screw 20 Va...

Page 10: ...e sure to include RMA number original receipt name return address and phone number in package In the event of a warranty claim please return the product postage prepaid with the origi nal receipt for...

Page 11: ...11 Model Serial Please keep a copy for your records 10 digit number by barcode on compressor unit MAINTENANCE NOTES...

Page 12: ...800 448 3873 Grant Michigan www easypropondproducts com info easypropondproducts com 9984 5 17...

Reviews: